Previous data on the survivorship of the Birmingham Hip Resurfacing (BHR) implant have come from design surgeons and large national databases outside of the United States, and there is a lack of reported outcomes of surface replacement arthroplasty from US centers. A retrospective study was undertaken of 1271 hips treated with a BHR system (Smith & Nephew, Memphis, Tennessee) between June 2006 and September 2008 at 6 high-volume total joint centers in the United States. Demographic features, Harris Hip Score (HHS), and radiographic findings were recorded. Patients who did not have a 2-year follow-up visit were contacted by telephone. All patients were asked about complications, reoperations, or failure of the implants. Of the treated hips, 1144 (90%) had a minimum of 2 years of clinical follow-up (mean, 2.9 years; range, 1.8-4.2 years). Mean age was 52.3 years, and 75% of patients were men. Mean HHS improved from 55.8 preoperatively to 97.4 at the most recent follow-up (P<.001). There were 16 (1.4%) revisions to total hip arthroplasty (THA) for fracture (7), early dislocation (3), acetabular component malpositioning with pain (3; 1 with metallosis), infection (1), femoral loosening (1), and pseudotumor (1). There were 9 additional complications (0.8%) that did not require revision, including 3 dislocations treated with closed reduction, 2 fractures, 3 nerve injuries, and 1 pseudotumor. At 2 to 4 years of follow-up, the revision rate and the major complication rate with the BHR system were similar to those in previous reports of primary THA. Excellent clinical results were observed, but further follow-up is necessary to assess mid-and long-term results with the BHR system in US patients.
机译:以前关于伯明翰HIP Resurfacing(BHR)植入物的生存的数据来自美国以外的设计外科医生和大型国家数据库,缺乏来自美国中心的表面替代关节造身术的结果。在2006年6月至2008年6月在美国的6个高批量总关节中心之间,在2006年6月至9月期间进行了1271髋的重新调整研究。记录了人口统计特征,哈里斯臀部评分(HHS)和射线照相调查结果。没有通过电话联系没有2年后续访问的患者。询问所有患者均对植入物的并发症,重新进展或失败。治疗的臀部,1144(90%)至少有2年的临床随访(平均,2.9岁;范围,1.8-4.2岁)。平均年龄为52.3岁,75%的患者是男性。平均HHS在最近的后续后续出现(P <.001)之前从术前从55.8提高到97.4。对于骨折(7),早期脱位(3),髋臼成分呈疼痛(3; 1带金属异位),感染(1),股骨宽松(1) ,伪压(1)。有9个另外的并发症(0.8%),不需要修改,包括用闭合的减少,2个裂缝,3个神经损伤和1个假瘤治疗的3个脱位。在2至4年的后续行动,修订率和BHR系统的主要并发症率类似于原发性THA的先前报告中的重复性。观察到出色的临床结果,但进一步的随访是在美国患者中使用BHR系统评估中期和长期结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号