...
首页> 外文期刊>Orthopedics >How frequent is rotational mismatch within 0°±10° in kinematically aligned total knee arthroplasty?
【24h】

How frequent is rotational mismatch within 0°±10° in kinematically aligned total knee arthroplasty?

机译:旋转不匹配在4°±10°内的旋转不匹配在运动膝关节间关节型成形术中的0°±10°内?

获取原文
获取原文并翻译 | 示例
           

摘要

Rotational mismatch of the tibial component on the femoral component within 0°±10° is associated with better function after mechanically aligned total knee arthroplasty (TKA). Kinematically aligned TKA has gained interest; however, the percentage of kinematically aligned TKA within 0°±10° is unknown. The authors prospectively followed all patients who underwent TKA for primary osteoarthritis between December 2011 and April 2012 (194 patients, 195 knees). Each underwent kinematically aligned TKA with manual instruments. Aligning the anteroposterior axis of the tibial component parallel to the line that bisects the oval boundary of the lateral tibial condyle set internal/external rotation. Removing bone from the posterior femoral condyles equal in thickness to the femoral component after correction for cartilage wear set internal/external rotation and anteroposterior translation of the femoral component. Rotational mismatch of the tibial component on the femoral component was determined from a computed tomography scan of the knee. Ninety-seven percent of kinematically aligned TKA with fixed-bearing components had a rotational mismatch within 0°±10° (overall range, -11° to 11°). This percentage was higher and the range narrower than the 85% of TKA within 0°±10° and the -14° to 16° range reported for mechanically aligned TKA. The use of manual instruments to kinematically aligned TKA reliably limited rotational mismatch to within 0°±10°, which has been associated with better function.
机译:在0°±10°内的股骨部件上的胫骨部件的旋转不匹配与机械对准的总膝关节置换术(TKA)进行更好的功能相关。运动学对齐的TKA已经获得了兴趣;然而,在0°±10°内的运动学上对齐的TKA的百分比是未知的。作者前瞻性地遵循了2011年12月至2012年12月至2012年4月(194名患者,195名膝盖)之间进行初级骨关节炎的所有患者。每个接受运动仪器的运动仪器的运动仪器。使胫骨部件的前后轴平行于向后分二分侧胫骨髁的椭圆形边界设定内部/外部旋转。在校正软骨磨损设定股骨组件的内/外旋转和前后平移后,从厚度等于厚度的股骨髁上除去厚度的股骨部件。从膝盖的计算机断层扫描确定股骨部件上的胫骨部件的旋转不匹配。含有固定轴承部件的97%的运动学对齐的TKA在0°±10°(总范围,-11°至11°)内具有旋转不匹配。该百分比较高,范围窄于85%的TKA在0°±10°内,并且报告用于机械对准的TKA的-14°至16°。使用手动仪器在运动学上对齐的TKA可靠地限制旋转不匹配在0°±10°内,这与更好的功能相关联。

著录项

  • 来源
    《Orthopedics》 |2013年第12期|共6页
  • 作者单位

    Orthopaedic Center for Musculoskeletal Research Orthop?dische Klinik K?nig-Ludwig-Haus;

    Biomedical Engineering Graduate Group University of California at Davis Davis CA United States;

    Orthopaedic Center for Musculoskeletal Research Orthop?dische Klinik K?nig-Ludwig-Haus;

    Biomedical Engineering Graduate Group University of California at Davis Davis CA United States;

    Biomedical Engineering Graduate Group University of California at Davis Davis CA United States;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 骨科学(运动系疾病、矫形外科学);
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号