Image restoration based on projection onto convex sets algorithm for beam modulation CT acquisition

机译:基于投影对凸起集CT采集凸起算法的图像恢复

获取原文
获取原文并翻译 | 示例
           

摘要

Recently, the use of a low-dose computed tomography (CT) system to reduce the radiation dose in medical imaging has been actively investigated. Region-of-interest (ROI) imaging is considered an effective method to reduce the exposure dose. Of the various studies of ROI imaging conducted in the medical field, most have not focused on improving the image quality of the entire anatomy. We propose ROI-based beam modulation acquisition to restore the information outside of the ROI. The CT system was simulated using the MAMAS R2017b program. The 3D voxelized phantom was made up of an abdominal DICOM image from a clinical CT system. A total of 360 projection data points were obtained, from which CT reconstructed images were obtained using a filtered back projection (FBP) reconstruction algorithm. The ROI CT images were reconstructed using the 360 truncated projection data points. Beam modulation CT images were reconstructed using 288 truncated and 72 full-size projection data points. An interpolation method and our proposed method based on a projection onto convex sets (POCS) algorithm corrected the truncated projection data. The image quality of three ROIs was evaluated using the structural similarity index measure (SSIM) value. Using beam modulation acquisition, it is possible to restore the external information of a reconstructed image. All ROI-based methods yield high SSIM values, close to 1, within the ROI. The reconstructed image obtained by beam modulation acquisition had a much higher SSIM value for the external information than that obtained by the ROI scan. According to the SSIM value, the proposed method based on a POCS algorithm provides the best image quality in beam modulation acquisition. In conclusion, we have verified the possibility of restoring the ROI external information using beam modulation acquisition. Additionally, we suggested a new restoration method based on a POCS algorithm to obtain better image quality in beam modulation acquisition.
机译:最近,已经主动研究了使用低剂量计算断层扫描(CT)系统以减少医学成像中的辐射剂量。兴趣区域(ROI)成像被认为是减少曝光剂量的有效方法。在医学领域进行的ROI成像的各种研究中,大多数人没有专注于改善整个解剖学的图像质量。我们提出基于ROI的光束调制采集来恢复ROI之外的信息。使用MAMAS R2017B程序模拟CT系统。 3D Voxized Phantom由来自临床CT系统的腹部DICOM图像组成。获得总共360个投影数据点,使用过滤的背部投影(FBP)重建算法来获得CT重建图像。使用360截短的投影数据点重建ROI CT图像。使用288截短和72个全尺寸投影数据点重建光束调制CT图像。基于投影到凸集(POCS)算法的插值方法和我们所提出的方法校正了截断的投影数据。使用结构相似性指数(SSIM)值评估三个ROI的图像质量。使用光束调制获取,可以恢复重建图像的外部信息。所有基于ROI的方法都会产生高SSIM值,在ROI内接近1。通过光束调制获取获得的重建图像对于外部信息的SSIM值比通过ROI扫描获得的更高的SSIM值。根据SSIM值,基于POCS算法的提出方法提供了光束调制采集中的最佳图像质量。总之,我们已经验证了使用波束调制采集恢复投资回报率外部信息的可能性。此外,我们建议了一种基于POCS算法的新恢复方法,从而获得光束调制采集中的更好的图像质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号