In many countries diagnostic medical exposures typically account for a very large fraction of the collective effective dose that can be assigned to anthropological sources and activities. This in part flags up the question of whether sufficient steps are being taken in regard to potential dose saving from such medical services. As a first step, one needs to survey doses to compare against those of best practice. The present study has sought evaluation of the radiation protection status and patient doses for certain key radiological procedures in four film-based radiology departments within Sudan. The radiation exposure survey, carried out using a survey meter and quality control test tools, involved a total of 299 patients their examinations being carried out at one or other of these four departments. The entrance surface air kerma (ESAK) was determined from exposure settings using DosCal software and an Unfors-Xi-meter. The mean ESAK for x-ray examination of the chest was 0.30 +/- 0.1 mGy, for the skull it was 0.96 +/- 0.7 mGy, for the abdomen 0.85 +/- 0.01 mGy, for spinal procedures 1.30 +/- 0.6 mGy and for procedures involving the limbs it was 0.43 +/- 0.3 mGy. Ambient dose-rates in the reception area, at the closed door of the x-ray room, recorded instantaneous values of up to 100 pSv/h. In regard to protection, the associated levels were found to be acceptable in three of the four departments, corrective action being required for one department, regular quality control also being recommended.
机译:在许多国家,诊断医疗风险通常估计可以分配给人类学来源和活动的集体有效剂量的非常大。这部分标志着关于从这些医疗服务的潜在剂量储存的潜在剂量措施是否采取了足够的步骤的问题。作为第一步,需要调查剂量以与最佳实践的剂量进行比较。本研究寻求评估苏丹四种基于胶片放射科部门的某些关键放射手术的辐射保护状态和患者剂量。使用测量仪和质量控制测试工具进行的辐射曝光调查,涉及在这四个部门中的一个或其他人进行的299名患者。入口表面空气Kerma(ESAK)由使用Doscal Software和Unfring-xi-meter从曝光设置确定。胸部X射线检查的平均esak为0.30 +/- 0.1迈克,对于颅骨为0.96 +/- 0.7米,为腹部0.85 +/- 0.01迈克,脊柱手术1.30 +/- 0.6 MGY对于涉及肢体的程序,它为0.43 +/- 0.3米。接收区域的环境剂量率,位于X射线室的闭门处,刻录瞬时值高达100 psv / h。关于保护,在四个部门中的三个部门中发现了相关的水平,为一个部门所需的纠正措施,也建议进行定期的质量控制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号