首页> 外文期刊>Radiation Physics and Chemistry >Photoneutron radiation field of ducts in barrier of 15 MV medical electron accelerators
【24h】

Photoneutron radiation field of ducts in barrier of 15 MV medical electron accelerators

机译:15 MV医用电子促进剂屏障管道的光敏龙辐射领域

获取原文
获取原文并翻译 | 示例
           

摘要

Shielding body of the high-energy medical electron accelerators is always penetrated by ducts, which would influence the shielding capability of local barrier. In order to quantitatively analyze the duct's impact on shielding of the photoneutron from 15 MV accelerators, the ambient dose equivalent rate and energy spectrum at the center of a typical duct and the external mouth of duct were calculated based on MCNP program for the first time. The results demonstrate that leakage neutrons at the external mouth of duct are mainly thermal neutron, and its dose rate is decreased with the increase of the intersection angle between duct and wall as well as the reduction of duct diameter. When a duct in a diameter no more than 30 cm penetrates the wall unidirectionally and the inclined Angle (theta) is 60 degrees, neutron dose rate at the external mouth of duct could meet the requirements of protection. At last, according to the calculation results, some suggestions are proposed for the shielding design of ducts in walls.
机译:高能医疗电子加速器的屏蔽体始终被管道渗透,这将影响局部屏障的屏蔽能力。为了定量分析导管对光敏龙的影响,从15 MV加速器的影响,第一次基于MCNP程序计算典型管道中心和管道中心的环境剂量等效速率和能谱。结果表明,管道外口处的泄漏中子主要是热中子,随着导管和壁之间的交叉角度的增加以及导管直径的减小,其剂量率降低。当直径不超过30厘米的管道直径单向穿透壁并且倾斜角度(θ)是60度时,管道外口的中子剂量率可以满足保护的要求。最后,根据计算结果,提出了一些建议,用于墙壁中的管道屏蔽设计。