首页> 外文期刊>Lung. >Proof of Concept: Very Rapid Tidal Breathing Nasal Nitric Oxide Sampling Discriminates Primary Ciliary Dyskinesia from Healthy Subjects
【24h】

Proof of Concept: Very Rapid Tidal Breathing Nasal Nitric Oxide Sampling Discriminates Primary Ciliary Dyskinesia from Healthy Subjects

机译:概念证明:非常快速的潮气呼吸鼻部一氧化氮抽样鉴别来自健康受试者的原发性睫状体障碍

获取原文
获取原文并翻译 | 示例
           

摘要

IntroductionNasal nitric oxide (nNO) is extremely low in individuals with primary ciliary dyskinesia (PCD) and is recommended as part of early workup. We investigated whether tidal breathing sampling for a few seconds was as discriminative between PCD and healthy controls (HC) as conventional tidal breathing sampling (cTB-nNO) for 20-30s.MethodsWe performed very rapid sampling of tidal breathing (vrTB-nNO) for 2, 4 and 6s, respectively. Vacuum sampling with applied negative pressure (vrTB-nNO(vac); negative pressure was applied by pinching the sampling tube) for <2s resulted in enhanced suction of nasal air during measurement. Feasibility, success rate, discriminatory capacity, repeatability and agreement were assessed for all four sampling modalities.ResultsWe included 13 patients with PCD, median (IQR) age of 21.8 (12.2-27.7)years and 17 HC, 25.3 (14.5-33.4)years. Measurements were highly feasible (96.7% success rate). Measured NO values with vrTB-nNO modalities differed significantly from TB-nNO measurements (HC: p<0.001, PCD: p<0.05). All modalities showed excellent discrimination. The vacuum method gave remarkably high values of nNO in both groups (1865 vs. 86ppb), but retained excellent discrimination. vrTB-nNO(4sec), vrTB-nNO(6sec) and vrTB-nNO(vac) showed identical specificity to cTB-nNO (all: 1.0, 95% CI 0.77-1.0).ConclusionvrTB-nNO sampling requires only a few seconds of probe-in-nose time, is feasible, and provides excellent discrimination between PCD and HC. Rapid TB-nNO sampling needs standardisation and further investigations in infants, young children and patients referred for PCD workup.
机译:引入纳米氧化氮(NNO)在具有原发性睫状体肽(PCD)的个体中非常低,建议作为早期掉后的一部分。我们调查了几秒钟的潮气呼吸抽样是PCD和健康控制(HC)之间的判别,作为20-30秒的常规潮气呼吸采样(CTB-NNO)。方法对潮汐呼吸(VRTB-NNO)进行了非常快速的采样。分别为2,4和6s。用施加的负压(VRTB-NNO(VAC);通过夹住采样管施加负压,为<2S施加负压,导致测量期间鼻空气的吸力增强。对所有四种采样模式进行评估可行性,成功率,歧视性能力,可重复性和协议。培养百合包括13名PCD患者,中位数(IQR)年龄21.8岁(12.2-27.7)岁及17 HC,25.3(14.5-33.4)年。测量是非常可行的(成功率为96.7%)。从TB-NNO测量测量测量VRTB-NNO模态的值没有显着不同(HC:P <0.001,PCD:P <0.05)。所有方式都表现出卓越的歧视。真空方法在两组中具有显着高的NNO值(1865 Vs.86ppb),但保留了良好的歧视。 VRTB-NNO(4SEC),VRTB-NNO(6SEC)和VRTB-NNO(VAC)对CTB-NNO(全部:1.0,95%CI 0.77-1.0)显示出相同的特异性.ConclusionVRTB-NNO采样只需要几秒钟探针 - 鼻部时间是可行的,并在PCD和HC之间提供出色的歧视。快速TB-NNO采样需要标准化,并进一步调查婴儿,幼儿和患者提到PCD工作的患者。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号