首页> 外文期刊>Nutrition Research >Proportional bias between dual-energy x-ray absorptiometry and bioelectrical impedance analysis varies based on sex in active adults consuming high- and low-carbohydrate diets
【24h】

Proportional bias between dual-energy x-ray absorptiometry and bioelectrical impedance analysis varies based on sex in active adults consuming high- and low-carbohydrate diets

机译:双能X射线吸收测定和生物电阻抗分析之间的比例偏压是基于消耗高碳水化合物饮食的活性成年人的性别

获取原文
获取原文并翻译 | 示例
           

摘要

Dual-energy x-ray absorptiometry (DXA) and bioelectrical impedance analysis (BIA) are common methods of body composition assessment, but the agreement between these methods varies. Bias between DXA and single-frequency BIA was evaluated at 6 different time points in 48 active male and female adults consuming standardized high- and low-carbohydrate diets. It was hypothesized that fixed and proportional biases exist between DXA and BIA but that the extent of bias does not differ based on sex. Substantial fixed bias was present for estimates obtained by DXA and BIA, and both men and women exhibited proportional bias for fat mass (FM) and fat-free mass (FFM). The magnitude of bias was greater in women, and only women exhibited proportional bias for body fat percentage. In individuals with less FM, the mean difference between DXA and BIA was high, indicating that BIA underestimated FM relative to DXA. However, in individuals with greater FM, better agreement was seen. Correspondingly, the mean difference in FFM estimates was greater in individuals with less FFM. In some individuals with high quantities of FM or FFM relative to the sample, the relationship between devices was reversed such that BIA overestimated FM and underestimated FFM. The degree of disagreement between DXA and BIA varies substantially based on body size and sex such that all-encompassing statements regarding the comparability of these technologies cannot presently be made. (C) 2017 Elsevier Inc. All rights reserved.
机译:双能X射线吸收测定法(DXA)和生物电阻抗分析(BIA)是人体成分评估的常见方法,但这些方法之间的协议各不相同。 DXA和单频BIA之间的偏差在48个活性雄性和女性成年人消耗标准化的高碳水化合物饮食中的6种不同的时间点评估。假设DXA和BIA之间存在固定和比例偏差,但偏差的程度并不基于性别不同。通过DXA和BIA获得的估计存在大量固定偏压,男性和女性对脂肪质量(FM)和无脂肪块(FFM)表现出比例偏差。女性偏差的大小更大,只有女性表现出体脂百分比的比例偏见。在FM较少的个体中,DXA和BIA之间的平均差异高,表明BIA相对于DXA低估了FM。但是,在具有更大FM的个人中,看到了更好的协议。相应地,FFM估计的平均差异在具有较少FFM的个体中更大。在相对于样品的一些具有高量FM或FFM的个体中,器件之间的关系颠倒,使得BIA高估FM并低估FFM。 DXA和BIA之间的分歧程度基本上基于体型和性别而变化,使得目前不能提出关于这些技术的可比性的全包陈述。 (c)2017年Elsevier Inc.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号