The analytical procedures for the reference measurements of cadmium and lead concentrations in four candidates for new environmental certified reference materials were developed. Cadmium and lead content was determined in bottom sediment (M-2 BotSed), Baltic herring tissue (M-3 HerTis), cormorant tissue (M-4 CormTis) and codfish tissue (M-5 CodTis). The measurements were carried out with the use of a direct isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS). The isotope dilution approach and the combined uncertainty of results are based on the mathematical equations as from definition of a primary method of measurement. All factors influencing the final results included: the procedural blank, the moisture content in the materials, the factors affecting the blend ratio measurements (instrumental background, spectral interferences, dead time, mass discrimination effects and the repeatability of measured isotopic ratios) as well as the isotopic equilibrium were systematically investigated and included in the uncertainty budget. The content of cadmium in candidates for new environmental reference materials, after correction for moisture contents, matrix separation on ion-exchange resin AG1-X8 of the blended samples and after using for the ICP-MS measurements ratio of pair of isotopes n(110Cd)/n(111Cd) was found to be: (2.18 +/- 0.06) mu g g(-1) in M-2 BotSed, (337 +/- 2) ng g(-1) in HerTis, (16.4 +/- 0.6) ng g(-1) in CormTis) and (2.7 +/- 0.4) ng g(-1) in CodTis, respectively. The content of lead in candidates for new environmental reference materials, after correction for moisture contents, matrix separation on ion-exchange resin AG1-X8 of the blended samples and after using for the ICP-MS measurements ratio of pair of isotopes n(Pb-208)/n(Pb-207) was found to be: (108 +/- 5) ng g(-1) in M-3 HerTis, (2.34 +/- 0.12) mu g g(-1) in M-4 CormTis and (43 +/- 2) ng g(-1) in M-5 CodTis, respectively. The Cd and Pb contents determined in this work were us
机译:开发了新的环保认证参考资料四个候选镉和铅浓度参考测量的分析程序。镉和铅含量在底部沉积物(M-2泊打),波罗的海鲱鱼组织(M-3赫斯蒂斯),鸬鹚组织(M-4 Cormtis)和鳕鱼组织(M-5 Codtis)中确定。通过使用直接同位素稀释电感耦合等离子体质谱(ID ICP-MS)进行测量。同位素稀释方法和结果的组合不确定度基于从主要测量方法的定义的数学方程式。影响最终结果的所有因素包括:程序坯料,材料中的水分含量,影响混合比测量的因素(仪器背景,光谱干扰,死区时间,质量辨别效果和测量同位素比率的可重复性)以及系统地调查同位素均衡并包含在不确定性预算中。新型环境参考资料候选物中镉的含量,校正水分含量后,在混合样品的离子交换树脂Ag1-X8上的基质分离,并使用Acp-MS测量比的同位素N(110cd)之后发现(111CD)是:(2.18 +/- 0.06)mu gg(-1)在赫斯蒂斯的M-2泊点(337 +/- 2)ng(-1)中,(16.4 +/-在Cormtis中为0.6)Ng(-1))和(2.7 +/- 0.4)Ng g(-1)在Codtis中。新型环境参考资料候选物中铅的含量,校正水分含量后,混合样品离子交换树脂Ag1-X8上的基质分离,并使用对同位素的ICP-MS测量比(PB-发现208)/ N(PB-207)是:(108 +/- 5)Ng G(-1)在M-3赫斯蒂斯,(2.34 +/- 0.12)mu gg(-1)中的m-4 CORMTIS和(43 +/- 2)NG G(-1)分别在M-5 CODTIS中。在这项工作中确定的CD和PB内容是我们

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号