We propose a non-contrast-enhanced, three-dimensional, free-breathing, electrocardiogram-gated, gradient recalled echo sequence with a slab-selective inversion for pulmonary vein (PV) MRI. A sagittal inversion slab was applied prior to data acquisition to suppress structures adjacent to the left atrium (LA) and PVs, thereby improving the conspicuity of the PV and LA. Compared with other MR angiography methods using an inversion pulse, the proposed method does not require signal subtraction and the inversion slab is not parallel to the imaging slab. The feasibility of the proposed method was demonstrated in healthy subjects. The inversion slab thickness and inversion time were optimized to be 60 mm and 500 ms, respectively. Compared to conventional gradient recalled echo imaging without inversion, the proposed technique significantly increased the contrast-to-noise ratios between the LA and the right atrium by 20-fold (P < 0.01), increased the contrast-to-noise ratios between the PVs and right atrium by 10-fold (P < 0.03), and increased the contrast-to-noise ratios between the PVs, LA and pulmonary artery by 4-fold (P < 0.01 for both). The signal-to-noise ratios of the PVs and the LA were similar with and without the inversion slab (P > 0.3). The proposed technique greatly enhances the conspicuity of the PVs and LA without significant loss of signal-to-noise ratio.
机译:我们提出了一种非对比度增强,三维,自由呼吸,心电图梯度召回的回波序列,具有肺静脉(PV)MRI的平板选择性反转。在数据采集之前应用矢状反转板以抑制与左心房(LA)和PVS相邻的结构,从而改善PV和LA的阴部。与使用反转脉冲的其他MR血管造影方法相比,所提出的方法不需要信号减法,并且反转板不平行于成像板。该方法的可行性在健康受试者中证明。反转板厚度和反转时间分别优化为60 mm和500ms。与传统梯度召回的回声成像相比,无反转,所提出的技术显着提高了La和右心中的对比度比率20倍(P <0.01),增加了PVS之间的对比度噪音比率右中庭通过10倍(p <0.03),并增加PVS,LA和肺动脉之间的对比度比4倍(两者P <0.01)。 PVS和La的信噪比与反转板(P> 0.3)类似。所提出的技术大大增强了PVS和LA的阴部,而不会显着丧失信噪比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号