首页> 外文期刊>European radiology >Learning curve of liver stiffness measurement using a new hybrid machine composed of transient elastography interfaced with ultrasound
【24h】

Learning curve of liver stiffness measurement using a new hybrid machine composed of transient elastography interfaced with ultrasound

机译:使用超声波连接的新型混合机组学习肝硬化测量曲线

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives To assess the learning curve for performing reliable liver stiffness measurements using a new hybrid machine composed of transient elastography (TE) interfaced with an ultrasound device for radiographers and radiologists with different levels of expertise in ultrasound imaging. Methods Ten novice operators who had never performed TE measurements were prospectively evaluated from April to October 2018: senior radiologists, young radiologists, fellows, radiographers, and residents, with different levels of experience in abdominal ultrasound imaging. All operators had a short theoretical training followed by a training session under supervision in three patients. Then, each operator had to perform TE in 50 consecutive patients with chronic liver disease, using beforehand ultrasound examination to select measurement area in the right liver lobe, and if needed, the XL probe. Percentages of failures and reliable measurements were compared. Results The rates of failures of measurements, poorly reliable, reliable, and very reliable results, were of 4.2% (21/500), 2.4% (12/500), 47.6% (238/500), and 45.8% (229/500), respectively. The rates of reliable plus very reliable results were excellent, ranging from 91 to 96% among all the subgroups. The rates of very reliable, reliable, and unreliable results did not differ between operator subgroups and especially between junior radiologists, senior radiologists, and radiographers. No breaking point was observed in the interquartile range/median values over time. Conclusion TE interfaced with ultrasound in this hybrid machine presents no learning curve effect. After a short initial training session, a novice observer is able to perform high rates of reliable and very reliable TE measurements.
机译:目标是使用由瞬态弹性摄影(TE)组成的新的混合机来评估用于执行可靠的肝脏刚度测量的学习曲线,该瞬态弹性摄影(TE)与超声装置和超声成像中具有不同专业级别的放射学家组成的瞬态弹性摄影(TE)。方法从2018年4月到10月至10月,加入了大量测量的10个新手运营商:高级放射科医生,年轻放射科医生,参与者和居民,具有不同的腹部超声成像水平。所有运营商都有一个简短的理论培训,然后在三名患者监督下进行培训课程。然后,每个操作员必须在连续50例慢性肝病患者中进行TE,使用事先的超声检查选择右肝叶中的测量区域,如果需要,XL探针。比较失败和可靠测量的百分比。结果测量的失败率,可靠,可靠,可靠,结果非常可靠,均为4.2%(21/500),2.4%(12/500),47.6%(238/500)和45.8%(229 /分别为500)。可靠加上非常可靠的结果的率优异,在所有亚组中的91%至96%。操作员亚组之间的速率非常可靠,可靠和不可靠的结果在初级放射科,高级放射科和放射摄影师之间没有区别。随着时间的推移,在狭隘的范围/中位值中没有观察到断裂点。结论本混合机中超声波连接的TE呈现出学习曲线效应。在初步训练期短暂之后,新手观察者能够执行高率可靠且非常可靠的TE测量。

著录项

  • 来源
    《European radiology》 |2020年第2期|共8页
  • 作者单位

    Univ Hosp Montpellier St Eloi Hosp Dept Diagnost &

    Intervent Radiol 80 Ave Augustin Fliche F;

    Univ Hosp Montpellier St Eloi Hosp Dept Diagnost &

    Intervent Radiol 80 Ave Augustin Fliche F;

    Univ Hosp Montpellier St Eloi Hosp Dept Diagnost &

    Intervent Radiol 80 Ave Augustin Fliche F;

    Univ Hosp Montpellier St Eloi Hosp Dept Diagnost &

    Intervent Radiol 80 Ave Augustin Fliche F;

    Univ Hosp Montpellier St Eloi Hosp Dept Diagnost &

    Intervent Radiol 80 Ave Augustin Fliche F;

    Univ Hosp Montpellier Dept Med Informat Montpellier France;

    Univ Hosp Montpellier St Eloi Hosp Dept Diagnost &

    Intervent Radiol 80 Ave Augustin Fliche F;

    Univ Hosp Montpellier St Eloi Hosp Dept Diagnost &

    Intervent Radiol 80 Ave Augustin Fliche F;

    Univ Hosp Montpellier St Eloi Hosp Dept Diagnost &

    Intervent Radiol 80 Ave Augustin Fliche F;

    Univ Hosp Montpellier St Eloi Hosp Dept Diagnost &

    Intervent Radiol 80 Ave Augustin Fliche F;

    Univ Hosp Montpellier St Eloi Hosp Dept Diagnost &

    Intervent Radiol 80 Ave Augustin Fliche F;

    Univ Hosp Montpellier St Eloi Hosp Dept Diagnost &

    Intervent Radiol 80 Ave Augustin Fliche F;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 放射医学;
  • 关键词

    Liver fibrosis; Elasticity imaging techniques; Ultrasonography; Learning curve; Clinical competence;

    机译:肝纤维化;弹性成像技术;超声检查;学习曲线;临床能力;