首页> 外文期刊>International Orthopaedics >Results with eight and a half?years average follow-up on two hundred and eight e-Motion FP? knee prostheses, fitted using computer navigation for knee osteoarthritis in patients with over ten degrees genu varum
【24h】

Results with eight and a half?years average follow-up on two hundred and eight e-Motion FP? knee prostheses, fitted using computer navigation for knee osteoarthritis in patients with over ten degrees genu varum

机译:结果八年半是八年的平均随访二百八八e-motion fp? 膝关节假体,适用于膝关节骨关节炎的计算机导航,患者患者超过十个华盛顿

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Purpose The aim of this study was to analyse the clinical and radiographic results of 208 e-Motion? posterior cruciate-retaining, mobile bearing prostheses (BBraun-Aesculap, Tuttlingen, Germany) fitted using computer navigation, for knee osteoarthritis with a genu varum greater than 10°. Methods One hundred ninety-two patients were operated on with 208 e-Motion? prostheses fitted, between January 2006 and December 2011, using the OrthoPilot? computer navigation system. Average pre-operative IKS score was 70?±?27 points (6-143) with a function score of 38?±?20.5 (0-90) and a knee score of 32.5?±?13 (0-63). Average flexion was 116.5°?±?13° (65-140°). Average pre-operative HKA angle was 166°?±?3° (154-169°). Results 2Results are available for 134 patients, with a total of 150 knees operated on (38 lost to follow-up and 20 deceased). Average follow-up was 104.5?months (60-116?months). On last follow-up, the average IKS was 180?±?22 points (95-200) with 86.5?±?16 points (25-100) for the function score and 93.5?±?8 points (55-100) for the knee score. Knee flexion was 116°?±?10.5° (80-135°) and average HKA angle was 179°?±?2° (175-184°). The pre-operative objective was achieved in 90.5% of knees. Conclusion The e-Motion? mobile bearing posterior cruciate-retaining prosthesis, fitted using computer navigation, offers excellent results after an average of 8.5?years follow-up. These results are at least equivalent, even superior, to those of the posterior-stabilised prostheses usually used for this type of deformity.
机译:摘要目的本研究的目的是分析208 e-motion的临床和放射线照相结果?靠在后曲,移动轴承假体(BBraun-Aesculap,Tuttlingen,德国)使用计算机导航,用于膝关节骨关节炎,现场曲线大于10°。方法使用208 e-Motion运营一百九十二名患者吗? 2006年1月至2011年12月在2011年12月之间使用了假肢,使用了orthopilot?计算机导航系统。平均术前IKS得分为70?±27分(6-143),功能得分为38?±20.5(0-90),膝关节分数为32.5?±13(0-63)。平均屈曲为116.5°θ±13°(65-140°)。平均术前的HKa角度为166°θ±3°(154-169°)。结果2患者提供2,共有150名膝盖,共有150名膝盖(38岁以下,后续行动和20日)。平均随访时间为104.5?月份(60-116?月)。最后的后续行动,平均IKS为180?±22分(95-200),功能得分为86.5?±16分(25-100),93.5?±8分(55-100)膝盖分数。膝关节屈曲为116°?±10.5°(80-135°)和平均HKA角度为179°→2°(175-184°)。在膝盖90.5%的膝盖上实现了术前目标。结论电子运动?使用计算机导航拟合电脑导​​航的移动轴承后旋转假体,平均提供优异的结果8.5?年后续随访。这些结果至少等同于通常用于这种类型的畸形的后稳定假体的那些。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号