首页> 外文期刊>International journal of structural stability and dynamics >Passive Control Analysis and Design of Twin-Tower Structure with Chassis
【24h】

Passive Control Analysis and Design of Twin-Tower Structure with Chassis

机译:底盘双塔结构的被动控制分析与设计

获取原文
获取原文并翻译 | 示例
           

摘要

In this paper, a symmetrical twin-tower structure with chassis connected with passive dampers is coupled as 2-DOF (degree of freedom) model. Using the stationary white noise as seismic excitation, the frequency-response function and the vibration energy expression of the symmetrical twin-tower structure are established based on the simplified 2-DOF model. Furthermore, based on the principle of minimum energy, the analytical expressions of the optimization parameters of two kinds of passive dampers are deduced, and the effectiveness of the dampers with optimized coefficients on structural control is verified by numerical examples of 2-DOF and MDOF (multi-degree-of-freedom) systems, respectively. Finally, the control effects of the two kinds of dampers under different control strategies on the responses of displacement of the top, base shear, structural vibration energy, and maximum inter-story drift of the symmetrical twin-tower structure are discussed through three-dimensional finite element numerical examples. It is verified that the analytical expressions of optimum parameters of the two kinds of dampers proposed based on the 2-DOF model are also beneficial to reduce the responses of the MDOF systems and actual engineering.
机译:在本文中,具有与无源阻尼器连接的底盘的对称双塔结构耦合为2-DOF(自由度)模型。使用静止白噪声作为地震激励,基于简化的2-DOF模型建立了对称双塔结构的频率响应函数和振动能量表达。此外,基于最小能量的原理,推导出两种无源阻尼器的优化参数的分析表达,并且通过2-DOF和MDOF的数值示例验证了在结构控制上具有优化系数的阻尼器的有效性(多程度自由度)系统。最后,通过三维讨论了通过三维讨论了对对称双塔结构的顶部,基部剪切,结构振动能量的响应和对称双塔结构的最大故事漂移的不同控制策略下的控制效应。有限元数值例。验证,基于2-DOF模型提出的两种阻尼器的最佳参数的分析表达也有利于减少MDOF系统和实际工程的响应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号