...
首页> 外文期刊>International journal of computerized dentistry >Optical profilometry versus intraoral (handheld) scanning In vitro feasibility study of vertical wear measurement
【24h】

Optical profilometry versus intraoral (handheld) scanning In vitro feasibility study of vertical wear measurement

机译:光学轮廓测定与口腔内(手持式)扫描垂直磨损测量的体外可行性研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Aim: The aim of this study was to evaluate the difference in maximum height loss values obtained from datasets based on optical profilometry and intraoral scanning. Additionally, two analysis applications were tested with respect to their correspondence. Materials and methods: To obtain baseline data, the occlusal surface of a metal phantom tooth was scanned by optical profilometry [WLP] and an intraoral scanner [IOS]. Then, wear was simulated at two locations of the tooth, three times each ([wear1], [wear2], and [wear3]), and the surface was captured after each status of wear, applying [WLP] and [IOS]. The maximum vertical height loss was evaluated by comparing the 3D datasets of [WLP] and [IOS] at [wear1], [wear2], and [wear3] with the baseline data of [WLP] and [IOS], respectively. For this purpose, two commercially available applications, Geo-magic Qualify and Oracheck, were used. Results: Apart from one outlier of 16% difference between the data obtained from [WLP] and [IOS], the maximum difference was 12.6%, which was equal to a metrical value of 15μm. For the corresponding values, which were calculated with Geomagic Qualify and Oracheck at identical wear facets, maximum differences between +7% and -6.7% were obtained. Conclusions: According to this in vitro study, the wear measurement on the basis of [IOS] seems to be a cost-effective, quick, and easily applicable tool for clinical screening purposes, with an acceptable reliability. With respect to the minor variations between each other, the Geomagic Qualify and Oracheck measurement applications are equivalent.
机译:目的:本研究的目的是评估基于光学轮廓测量和口内扫描的数据集获得的最大高度损失值的差异。另外,对其对应关系测试了两种分析应用。材料和方法:为了获得基线数据,通过光学轮廓测定器[WLP]扫描金属模齿的咬合表面和内部扫描仪[iOS]。然后,在牙齿的两个位置模拟磨损,每个位置(λ,λ和λ),并且在磨损的每个状态之后捕获表面,施加[WLP]和[iOS]。通过将[WLP]和[IOS]的3D数据集与[WLP]和[iOS]的基线数据进行比较,通过将[WLP]和λ和λ和[iOS]的基线数据进行比较来评估最大垂直高度损耗。为此目的,使用了两个商业上可用的应用,地理魔法资格和Oracheck。结果:除了从[WLP]和[iOS]获得的数据之间的16%差异,最大差异为12.6%,等于度量为15μm。对于用地磁资格和Oracheck计算的相应值,在相同的磨损方面计算,获得+ 7%和-6.7%之间的最大差异。结论:根据这项体外研究,基于[iOS]的磨损测量似乎是临床筛查目的的成本效益,快速,适用的工具,具有可接受的可靠性。关于彼此之间的次要变化,地质资格和Oracheck测量应用是等效的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号