The present work consists of a parametric study of a double wall separated by an air layer within PCM panels, exposed to solar radiation. This experimental study was conducted using two real-scale test cavities, located in the Faculty of Science Ain Chock - Casablanca, for active and passive cases. For this purpose, many thermocouples are used for the thermal control of indoor applications, as well as for measuring the temperature field of the air layer within PCM. The evolution of the measured temperatures will make it possible to calculate the heat fluxes densities exchanged through the walls to explore heat transfer inside the air layer with PCM. The results show that the temperature fluctuations. are reduced by 1.8°C for the internal face of the studied wall and by 1°C for the indoor temperature of the room with PCM compared to the reference room.
机译:本工作包括由PCM面板内的空气层分开的双壁的参数研究,暴露于太阳辐射。 该实验研究是使用两个实际测试空腔进行的,位于科学街科卡萨布兰卡科学学院,用于主动和被动案例。 为此目的,许多热电偶用于室内应用的热控制,以及测量PCM内的空气层的温度场。 测量温度的演化将使可以计算通过壁交换的热量密度,以利用PCM探讨空气层内的热传递。 结果表明温度波动。 对于所研究的壁的内面和1°C的室内温度与PCM相比,减少了1.8°C,与参考室相比,通过PCM的室内温度。