首页> 外文期刊>Acta Neurochirurgica >Diagnostic efficacy of Hounsfield units in spine CT for the assessment of real bone mineral density of degenerative spine: correlation study between T-scores determined by DEXA scan and Hounsfield units from CT
【24h】

Diagnostic efficacy of Hounsfield units in spine CT for the assessment of real bone mineral density of degenerative spine: correlation study between T-scores determined by DEXA scan and Hounsfield units from CT

机译:Hounsfield单位在脊柱CT中对变性脊柱的真实骨矿物质密度评估的诊断功效:DEXA扫描确定的T评分与CT的Hounsfield单位之间的相关性研究

获取原文
获取原文并翻译 | 示例
           

摘要

Dual-energy X-ray absorptiometry (DEXA) scan is an easy and cost-effective method of assessing bone mineral density (BMD). However, in patients with degenerative changes of the spine, overestimation of T-score on DEXA scan can occur despite low BMD during pedicle screw placement in spine surgery. The goal of this study is to assess BMD using Hounsfield unit (HU) measurements from computed tomography (CT) and to correlate these with DEXA-assessed T-scores in non-degenerative and degenerative patients.
机译:双能X射线骨密度仪(DEXA)扫描是一种评估骨矿物质密度(BMD)的简便且经济高效的方法。但是,在脊柱退行性改变的患者中,尽管在脊柱外科手术中在椎弓根螺钉置入过程中BMD低,但在DEXA扫描中T分数可能会被高估。这项研究的目的是使用计算机断层扫描(CT)的Hounsfield单位(HU)测量来评估BMD,并将其与DEXA评估的非变性和变性患者的T分数相关联。