...
首页> 外文期刊>Acta Radiologica >Diffusion tensor imaging findings of the median nerve before and after carpal tunnel corticosteroid injection in patients with carpal tunnel syndrome: a preliminary study
【24h】

Diffusion tensor imaging findings of the median nerve before and after carpal tunnel corticosteroid injection in patients with carpal tunnel syndrome: a preliminary study

机译:腕管综合征患者腕管皮质类固醇注射前后的中位神经扩散张量成像结果:初步研究

获取原文
获取原文并翻译 | 示例
           

摘要

Background Corticosteroid injections are a popular technique for carpal tunnel syndrome (CTS) treatment and are believed to provide rapid symptom relief. Purpose To use magnetic resonance diffusion tensor imaging (MR-DTI) to determine the association between diffusion values of the median nerve (MN) at several anatomic locations and symptom relief in patients with CTS following corticosteroid injection. Material and Methods MR-DTI was performed on 15 wrists of 12 patients with CTS before and two weeks after ultrasound-guided corticosteroid injections. We recorded the patients' clinical data including sex, age, side of injection, satisfaction, and symptom relief. Satisfaction and symptom relief were rated using a Likert scale and the Boston Carpal Tunnel Syndrome Questionnaire (BCTQ) scale. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) of the MN at the levels of the distal radioulnar joint (DRUJ), pisiform bone, and hamate bone were determined. Results All patients had = 50% satisfaction on the injection side. In comparison with baseline values, post-injection ADC was significantly lower (P = 0.001) but FA was not significantly higher (P = 0.11) at the pisiform bone level on the injected wrists. At the DRUJ and hamate bone levels, no obvious inter-scan change in FA and ADC (P 0.05) was observed. The decrease in ADC at the pisiform bone level strongly correlated with the decrease in BCTQ scores (r = 0.628; P = 0.012). Conclusion Symptom relief in patients with CTS receiving corticosteroid injection is related to the change in ADC of the median nerve at the level of the pisiform bone, as determined using MR-DTI.
机译:背景技术皮质类固醇注射是腕管综合征(CTS)治疗的流行技术,并被认为提供快速症状浮雕。目的用来使用磁共振扩散张量成像(MR-DTI)来确定CTS在皮质类固醇注射后CTS患者的几个解剖学位置和症状缓解中中值神经(MN)之间的关联。材料和方法MR-DTI在超声引导的皮质类固醇类固醇液之前和两周后的12名CTS的15名患者中进行。我们记录了患者的临床数据,包括性别,年龄,注射,满意度和症状浮雕。使用李克特量表和波士顿腕管综合征问卷(BCTQ)规模评定满意和症状救济。测定了远端Radioulnar接头(DRUJ),基本骨和Hamate骨水平的Mn的分数各向异性(FA)和表观扩散系数(ADC)。结果所有患者均为& =注射侧的50%满意度。与基线值相比,注射后ADC显着降低(P = 0.001),但在注射的手腕上的基本骨水平上没有显着高(p = 0.11)。在Druj和Hamate骨水平下,未观察到FA和ADC(P> 0.05)中明显的扫描间变化。基部骨水平下的ADC的降低与BCTQ分数的降低强烈相关(r = 0.628; p = 0.012)。结论CTS接受皮质类固醇注射患者的症状浮雕与基本骨水平的中位神经的ADC变化有关,如使用MR-DTI测定的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号