Purpose: To evaluate the validity and reliability of alternative methods for evaluating meibomian gland (MG) dropout without using an infrared light system: red-filtered or isolated red-channel images (RCIs) of the everted eyelid. Methods: We evaluated MG dropout in the everted upper and lower eyelids of 125 eyes of 64 patients with good-quality infrared meibography images (IMIs) and color digital photographs with and without a red filter. Red-filtered images (RFIs) were converted to black and white and adjusted for contrast/brightness [ adjusted redfiltered images (aRFIs)]. RCIs were computationally isolated from color digital photographs obtained without a red filter. After randomization, the total meiboscore (0-6) was evaluated by 2 independent evaluators (interobserver reliability) masked to the image origin, and again after a 30-day interval (intraobserver reliability). Results: The meiboscores evaluated using the RFI, aRFI, and RCI were strongly positively correlated with those evaluated using the IMI (RFI: r = 0.788; aRFI: r = 0.735; RCI: r = 0.630; all P, 0.001, Spearman correlation analysis). Linear-weighted k-values (kw) showed substantial agreement between the RFI and IMI (kw = 0.676, 95% CI = 0.594-0.759). The RFI had substantial intraobserver reliability (kw = 0.735, 95% CI = 0.685-0.785) and moderate interobserver reliability (kw = 0.467, 95% CI = 0.371-0.563). Computational adjustment of RFIs did not enhance the validity or reliability, and RCIs had limitations in some cases. Conclusions: MGs were successfully visualized using a red filter on a slit lamp and showed substantial agreement with visualization using the standard infrared method. Although interobserver reliability was only moderate, this alternative technique may be useful for evaluating MG dropout when an infrared meibography device is not available.
机译:目的:为了评估肉桂腺(MG)辍学的替代方法的有效性和可靠性,而无需使用红外光系统:Everted眼睑的红滤布或孤立的红通道图像(RCI)。方法:我们在64名患者125只患者的高级红外令人友好的红外尺码图像(IMIS)和彩色数字照片中,评估了MG辍学率的64岁的眼睑下降,以及带有红色过滤器的彩色数字照片。将红色滤波图像(RFI)转换为黑色和白色,并调整对比度/亮度[调整后的RedFiltered图像(ARFIS)]。 RCI从没有红色滤光器获得的彩色数字照片被计算隔离。在随机化之后,通过屏蔽到图像来源的2个独立评估员(Interobserver可靠性)评估总孔芯片(0-6),并在30天间隔(intraobserver可靠性)之后再次评估。结果:使用RFI,ARFI和RCI评估的Meiboscores与使用IMI评估的麦博钻(RFI:R = 0.788评估的那些强烈呈正相关(RFI:R = 0.735; RCI:r = 0.630;所有P,0.001,Spearman相关分析)。线性加权k值(kW)显示RFI和IMI之间的大量协定(KW = 0.676,95%CI = 0.594-0.759)。 RFI具有大量的血管内检测器可靠性(KW = 0.735,95%CI = 0.685-0.785)和中度的Interobserver可靠性(KW = 0.467,95%CI = 0.371-0.563)。 RFI的计算调整没有提高有效性或可靠性,并且RCI在某些情况下有局限性。结论:MGS在狭缝灯上使用红色滤光片成功地可视化,并使用标准红外方法显示了与可视化的大量协议。虽然Interobserver可靠性仅适中,但是当不可用红外脚踏设备时,该替代技术对于评估MG丢失是有用的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号