Abstract The paper describes the conversion to a?new generation of descaling nozzles in a?conventional hot strip mill for steel. There are descaling stations behind the reheating furnace, on the roughing mill stands, and in front of the finishing mill. Before the converting, three high pressure pumps had been in operation to supply the descaling stations. The new descaling nozzles were tested first in the finishing mill descaler with good results. There were considerable water savings without compromising the descaling effect and the material surface quality. After a?successful test, the remaining descaling stations were converted accordingly. The overall water saving was approx. 20%, which allowed shutting off one of the three high-pressure pumps. The electrical energy saving amounts to 30,000?kWh/day or about 9,300,000?kWh/year. At the current energy costs, this is equivalent to about 642,000??. Additional advantages are also seen, such as reduced material cooling and the lower wear of the components of the whole high-pressure water hydraulic system.
机译:摘要纸张描述了钢中的常规热带磨机中的新一代除垢喷嘴的转换。再加热炉后面有除垢站,粗磨机上,粗磨机,在整理磨机前面。在转换之前,三个高压泵已经运行以供应除垢站。首先在精加工磨机除垢剂中首先测试新的除垢喷嘴。在不损害除垢效果和材料表面质量的情况下,有相当大的节水。经过一次?成功测试,相应地转换剩余的除垢站。整节水约为。 20%,允许关闭三个高压泵中的一个。电节电量为30,000?kWh /日或约9,300,000?kWh /年。在当前的能源成本,这相当于约642,000岁。还可以看到额外的优点,例如降低材料冷却和整个高压水液压系统的部件的较低磨损。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号