Explosions and fires are responsible for millions of dollars of losses in the chemical and/or oil & gas industries each year. Because such a great potential for loss exists, it's common for these industries to employ safety instrumented systems (SIS) to provide safe isolation of flammable or potentially toxic material in the event of a fire or accidental release of fluids. Typically, safety instrumented systems consist of three elements: 1. Field sensors used to collect information needed to determine if an emergency situation exists. These are dedicated to SIS service and have process taps that are separate and distinct from the normal process information. 2. A logic system that determines what action is to be taken based on the information gathered. Highly-reliable logic solvers are used that provide both fail-safe and fault-tolerant operation. 3. A final control element that implements the action determined by the logic system. This final control element is typically a pneumatically-actuated valve.
机译:爆炸和火灾每年在化学和/或石油和天然气行业中造成数百万美元的损失。由于存在如此巨大的损失潜力,因此这些行业通常会使用安全仪表系统(SIS),以在发生火灾或意外泄漏液体时安全隔离可燃或潜在有毒物质。通常,安全仪表系统由三个元素组成:1.现场传感器,用于收集确定紧急情况是否存在所需的信息。这些专用于SIS服务,并具有与常规过程信息不同的过程分接头。 2.一种逻辑系统,可根据收集的信息确定要采取的措施。使用高度可靠的逻辑求解器,可提供故障安全和容错操作。 3.最终控制元件,用于执行逻辑系统确定的动作。该最终控制元件通常是气动阀。

著录项

  • 来源
    《Control systems》 |2003年第3期|共9页
  • 作者

  • 作者单位
  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 计量学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号