首页> 外文期刊>Water Science and Technology >Controlling chemical dosing for sulfide mitigation in sewer networks using a hybrid automata control strategy
【24h】

Controlling chemical dosing for sulfide mitigation in sewer networks using a hybrid automata control strategy

机译:使用混合自动机控制策略控制化学剂量以减轻下水道网络中的硫化物

获取原文
获取原文并翻译 | 示例
           

摘要

Chemicals such as magnesium hydroxide (Mg(OH)_2) and iron salts are widely used to control sulfideinduced corrosion in sewer networks composed of interconnected sewer pipe lines and pumping stations. Chemical dosing control is usually non-automatic and based on experience, thus often resulting in sewage reaching the discharge point receiving inadequate or even no chemical dosing. Moreover, intermittent operation of pumping stations makes traditional control theory inadequate. A hybrid automata-based (HA-based) control method is proposed in this paper to coordinate sewage pumping station operations by considering their states, thereby ensuring suitable chemical concentrations in the network discharge. The performance of the proposed control method was validated through a simulation study of a real sewer network using real sewage flow data. The physical, chemical and biological processes were simulated using the well-established SeweX model. The results suggested that the HA-based control strategy significantly improved chemical dosing control performance and sulfide mitigation in sewer networks, compared to the current common practice.
机译:诸如氢氧化镁(Mg(OH)_2)和铁盐之类的化学物质被广泛用于控制由相互连接的下水管道和泵站组成的下水道网络中硫化物引起的腐蚀。化学剂量控制通常是非自动的,并且是基于经验的,因此经常导致到达排放点的污水接收到的化学剂量不足,甚至没有进行化学剂量控制。而且,泵站的间歇运行使传统的控制理论不足。提出了一种基于混合自动机(HA)的控制方法,通过考虑污水泵站的状态来协调污水泵站的运行,从而确保网络排放中合适的化学浓度。通过使用实际污水流量数据对真实下水道网络进行仿真研究,验证了所提出的控制方法的性能。使用成熟的SeweX模型模拟了物理,化学和生物过程。结果表明,与当前的常规做法相比,基于HA的控制策略显着改善了下水道网络中的化学剂量控制性能和硫化物缓解。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号