首页> 外文期刊>Transplantation Proceedings >Application of a self-made swivel intravenous transfusion device in constructing allogenic small bowel transplantation rejection model in rats.
【24h】

Application of a self-made swivel intravenous transfusion device in constructing allogenic small bowel transplantation rejection model in rats.

机译:自制旋转输液器在大鼠异体小肠移植排斥模型建立中的应用。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Lacking a long-term continuous intravenous infusion device for experimental animals is the biggest obstacle to constructing an allogenic small bowel transplantation rejection model. OBJECTIVE: To establish a rat heterotopic small bowel transplantation model with the use of a swivel device for intravenous transfusion. METHODS: The randomized block design of controlled observations included 90 inbred male F344/NCrl BR rats as donors and 90 LEW/Crl rats as recipients. On the basis of body weight, the rats were divided into three groups each with 30 pairs of rats. Group 1, the control group, underwent small bowel transplantation. Group 2, the transfusion group, received small bowel transplantation and continuous infusion of parenteral nutrient solution. Group 3, the tacrolimus (FK506) treatment group, received small bowel transplantation, continuous infusion of parenteral nutrient solution, and intravenous injection of FK506. The general status and survival time of transplanted rats were observed for 5 weeks. RESULTS: The operative success rate was 100%. The survival rate was 83.3% (25/30) in the control group; and 96.7% (58/60) in groups 2 and 3 (P = .039). The mean survival time of the FK506 group was 22.1 +/- 13.4 days, which was significantly higher than that in the transfusion group (10.4 +/- 2.9 days, P = .023). CONCLUSION: The simple, practical swivel intravenous infusion device provided treatment for more than 30 days, a useful tool for heterotopic segmental small bowel transplantation.
机译:背景:缺乏用于实验动物的长期连续静脉输液装置是构建同种异体小肠移植排斥模型的最大障碍。目的:利用旋转静脉输液装置建立大鼠异位小肠移植模型。方法:对照观察的随机区组设计包括90只自交雄性F344 / NCrl BR大鼠作为供体,以及90只LEW / Crl大鼠作为受体。根据体重将大鼠分为三组,每组30对。第1组,对照组,进行小肠移植。第2组,输血组,接受小肠移植并连续输注肠胃外营养液。他克莫司(FK506)治疗组的第三组接受小肠移植,连续输注肠胃外营养液并静脉注射FK506。观察移植大鼠的一般状况和存活时间5周。结果:手术成功率为100%。对照组生存率为83.3%(25/30);第2组和第3组的比例为96.7%(58/60)(P = .039)。 FK506组的平均生存时间为22.1 +/- 13.4天,明显高于输血组(10.4 +/- 2.9天,P = .023)。结论:简单,实用的旋转式静脉输液器可提供30天以上的治疗,是异位节段性小肠移植的有用工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号