Visual Enhancement of Laparoscopic Partial Nephrectomy With 3-Charge Coupled Device Camera: Assessing Intraoperative Tissue Perfusion and Vascular Anatomy by Visible Hemoglobin Spectral Response

机译:腹腔镜部分肾切除术与三电荷耦合设备相机的视觉增强:通过可见的血红蛋白光谱反应评估术中组织灌注和血管解剖学

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: We report the novel use of 3-charge coupled device camera technology to infer tissue oxygenation. The technique can aid surgeons to reliably differentiate vascular structures and noninvasively assess laparoscopic intraoperative changes in renal tissue perfusion during and after warm ischemia. Materials and Methods: We analyzed select digital video images from 10 laparoscopic partial nephrectomies for their individual 3-charge coupled device response. We enhanced surgical images by subtracting the red charge coupled device response from the blue response and overlaying the calculated image on the original image. Mean intensity values for regions of interest were compared and used to differentiate arterial and venous vasculature, and ischemic and nonischemic renal parenchyma.Results: The 3-charge coupled device enhanced images clearly delineated the vessels in all cases. Arteries were indicated by an intense red color while veins were shown in blue. Differences in mean region of interest intensity values for arteries and veins were statistically significant (p >0.0001). Three-charge coupled device analysis of pre-clamp and post-clamp renal images revealed visible, dramatic color enhancement for ischemic vs nonischemic kidneys. Differences in the mean region of interest intensity values were also significant (p <0.05). Conclusions: We present a simple use of conventional 3-charge coupled device camera technology in a way that may provide urological surgeons with the ability to reliably distinguish vascular structures during hilar dissection, and detect and monitor changes in renal tissue perfusion during and after warm ischemia.
机译:目的:我们报告了3电荷耦合设备相机技术在组织氧合方面的新颖应用。该技术可以帮助外科医生可靠地区分血管结构,并在热缺血期间和之后无创地评估腹腔镜术中肾组织灌注的术中变化。材料和方法:我们分析了从10个腹腔镜部分肾切除术中选择的数字视频图像,以了解它们各自的3电荷耦合器件响应。我们通过从蓝色响应中减去红色电荷耦合的设备响应并将计算出的图像覆盖在原始图像上来增强外科手术图像。比较感兴趣区域的平均强度值,并将其用于区分动脉和静脉脉管系统以及缺血性和非缺血性肾实质。结果:在所有情况下,三电荷耦合装置增强的图像清楚地描绘了血管。动脉显示为深红色,而静脉显示为蓝色。动脉和静脉的平均关注区域强度值的差异具有统计学意义(p> 0.0001)。钳前和钳后肾脏图像的三电荷耦合装置分析显示,缺血性和非缺血性肾脏可见,显着的颜色增强。平均兴趣区域强度值的差异也很显着(p <0.05)。结论:我们目前以简单的方式使用常规的3电荷耦合设备摄像头技术,可以为泌尿外科医师提供在肝门解剖期间可靠地区分血管结构并检测和监测温暖缺血期间和之后肾脏组织灌注变化的能力。 。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号