...
首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >A green method for the quantification of plastics-derived endocrine disruptors in beverages by chemometrics-assisted liquid chromatography with simultaneous diode array and fluorescent detection
【24h】

A green method for the quantification of plastics-derived endocrine disruptors in beverages by chemometrics-assisted liquid chromatography with simultaneous diode array and fluorescent detection

机译:化学计量学-辅助液相色谱-同时检测二极管阵列和荧光检测定量饮料中塑料衍生的内分泌干扰物的绿​​色方法

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to develop a novel analytical method for the determination of bisphenol A, nonylphenol, octylphenol, diethyl phthalate, dibutyl phthalate and diethylhexyl phthalate, compounds known for their endocrine-disruptor properties, based on liquid chromatography with simultaneous diode array and fluorescent detection. Following the principles of green analytical chemistry, solvent consumption and chromatographic run time were minimized. To deal with the resulting incomplete resolution in the chromatograms, a second-order calibration was proposed. Second-order data (elution time-absorbance wavelength and elution time-fluorescence emission wavelength matrices) were obtained and processed by multivariate curve resolution-alternating least-squares (MCR-ALS). Applying MCR-ALS allowed quantification of the analytes even in the presence of partially overlapped chromatographic and spectral bands among these compounds and the potential interferents. The obtained results from the analysis of beer, wine, soda, juice, water and distilled beverage samples were compared with gas chromatography-mass spectrometry (GC-MS). Limits of detection (LODs) in the range 0.04-038 ng mL(-1) were estimated in real samples after a very simple solid-phase extraction. All the samples were found to contain at least three EDs, in concentrations as high as 334 ng mL(-1). (C) 2016 Elsevier B.V. All rights reserved.
机译:这项研究的目的是基于液相色谱,同时二极管阵列和串联色谱,开发一种测定双酚A,壬基酚,辛基酚,邻苯二甲酸二乙酯,邻苯二甲酸二丁酯和邻苯二甲酸二乙基己酯的化合物的新型分析方法。荧光检测。遵循绿色分析化学原理,将溶剂消耗和色谱运行时间降至最低。为了解决色谱图中不完整的分离度,提出了二次校准方法。获得二阶数据(洗脱时间-吸光度波长和洗脱时间-荧光发射波长矩阵),并通过多元曲线分辨率-交替最小二乘(MCR-ALS)进行处理。即使在这些化合物和潜在的干扰物之间存在部分重叠的色谱带和光谱带,使用MCR-ALS仍可以对分析物进行定量。将啤酒,葡萄酒,苏打水,果汁,水和蒸馏饮料样品的分析结果与气相色谱-质谱法(GC-MS)进行比较。在非常简单的固相萃取后,实际样品中的检测限(LOD)估计为0.04-038 ng mL(-1)。发现所有样品均含有至少三种ED,浓度高达334 ng mL(-1)。 (C)2016 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号