首页> 外文期刊>Acta Horticulturae >Measurement of overall heat transfer coefficient of covering material with thermal screens for plastic greenhouse.
【24h】

Measurement of overall heat transfer coefficient of covering material with thermal screens for plastic greenhouse.

机译:用塑料温室热屏测量覆盖材料的总传热系数。

获取原文
获取原文并翻译 | 示例
           

摘要

Recent increases in fuel prices have forced growers to apply energy-saving measures in the air heated greenhouses. As a result, growers have been forced to consider innovative cover materials and they have been advised to install thermal screens. Materials used as greenhouse covers are not spatially homogeneous that's why the selection of a covering is crucial for attainment of an optimal controlled environment. Several attempts have been already made to develop measurement procedures applicable under conditions resembling those of greenhouse production on purpose to investigate the U-values of glazing materials by using a hot box. The objective of the present study was to investigate the overall heat transfer coefficient of greenhouse covering materials with or without thermal screens commonly used in the country under external and real conditions by using the hot box method. The test conditions of eight treatments combined covering materials and thermal screens with and without shelter from the sky radiation were used to determine the overall heat transfer coefficient. The insulation effect of two layers covering material is about 36% comparing to one layer covering material and the coefficient is 3.0 (W.m -2.K -1) less than one layer. The decrease of the coefficient of one layer and two layers coverings by shelter was about 30% and 24% respectively. When we measure the overall heat transfer coefficients in a laboratory, it is necessary to establish the measuring system to be able to simulate the sky radiation. CT International Symposium on New Technologies for Environment Control, Energy-Saving and Crop Production in Greenhouse and Plant Factory - Greensys 2013, Jeju, Korea Republic, 22-27 September 2013.
机译:最近燃油价格上涨迫使种植者在空气加热温室中采取节能措施。结果,种植者被迫考虑采用创新的覆盖材料,并被建议安装隔热屏。用作温室覆盖物的材料在空间上不是均匀的,这就是为什么选择覆盖物对于获得最佳受控环境至关重要的原因。已经进行了数种尝试来开发适用于类似于温室生产的条件的测量程序,目的是通过使用热箱来调查玻璃材料的U值。本研究的目的是使用热箱法研究该国在外部和实际条件下使用或不使用热屏的温室覆盖材料的整体传热系数。八种处理方法的测试条件结合了覆盖材料和热屏,有和没有遮挡天空辐射,用于确定总体传热系数。与一层覆盖材料相比,两层覆盖材料的绝缘效果约为36%,系数比一层小3.0(W.m -2.K -1)。遮盖物使一层和两层覆盖物的系数分别降低约30%和24%。当我们在实验室中测量整体传热系数时,有必要建立一种能够模拟天空辐射的测量系统。 CT国际温室和植物工厂环境控制,节能和作物生产新技术研讨会-Greensys 2013,韩国济州,2013年9月22日至27日。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号