首页> 外文期刊>Computers in Biology and Medicine >Diagnostic value of tissue harmonic imaging compared with conventional sonography.
【24h】

Diagnostic value of tissue harmonic imaging compared with conventional sonography.

机译:组织谐波成像与常规超声检查相比的诊断价值。

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study was to determine if tissue harmonic imaging (THI) produced diagnostic images more frequently than conventional sonography. A prospective study was performed on 33 patients, to compare the diagnostic value of THI with conventional sonography. Each examination was performed using THI (transmit frequency=2.0MHz, receive frequency=4.0MHz) and conventional sonography at 2.5 and 4.0MHz. The different sonographic techniques were then graded as to whether they produced diagnostic images. THI produced diagnostic images in 33 of 33 examinations (100%), 2.5MHz conventional sonography produced diagnostic images in 26 of 33 examinations (79%), and 4.0MHz conventional sonography produced diagnostic images in 26 of 33 examinations (79%). THI produced diagnostic images significantly more frequently than 2.5MHz conventional sonography (p=.0233) and 4.0MHz conventional sonography (p=.0233). The THI technique produced diagnostic images more frequently than conventional sonography.
机译:这项研究的目的是确定组织谐波成像(THI)是否比常规超声更频繁地产生诊断图像。对33例患者进行了一项前瞻性研究,以比较THI与常规超声检查的诊断价值。每次检查均使用THI(发射频率= 2.0MHz,接收频率= 4.0MHz)和常规超声检查在2.5和4.0MHz进行。然后对不同的超声检查技术进行分级,以确定它们是否产生诊断图像。 THI在33个检查中的33个(100%)中产生了诊断图像,2.5MHz常规超声在33个检查中的26个(79%)中产生了诊断图像,而4.0MHz传统超声在33个检查中的26个(79%)中产生了诊断图像。与2.5MHz常规超声检查(p = .0233)和4.0MHz常规超声检查(p = .0233)相比,THI产生诊断图像的频率明显更高。 THI技术比常规超声检查产生诊断图像的频率更高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号