In glow discharge mass spectrometry (GDMS) and glow discharge optical emission spectrometry (GDOES), variations in the signal intensities against the discharge parameters: current, voltage and the pressure of plasma gas, are compared to clarify their excitation/ionization processes responsible to each signal. The behaviors are dependent on the discharge mode, i.e., constant-voltage and constant-pressure conditions. Under the constant-voltage conditions where the gas pressure is varied, the ion intensities in GDMS have a maximum and then decrease at higher discharge currents, while the emission intensities in GDOES monotonically increase along with the discharge current. On the other hand, similar dependence of their signal intensities on the discharge current is observed under the constant-pressure conditions. These results indicate that the transport process of analyte ions produced in the plasma play an important role in determining the ion intensities in GDMS.
机译:在辉光放电质谱法(GDMS)和辉光放电光发射光谱法(GDOES)中,比较了信号强度相对于放电参数的变化:电流,电压和等离子气体的压力,以阐明它们各自引起的激发/电离过程。信号。行为取决于放电模式,即恒定电压和恒定压力条件。在气压变化的恒压条件下,GDMS中的离子强度最大,然后在较高的放电电流下降低,而GDOES中的发射强度随放电电流单调增加。另一方面,在恒定压力条件下观察到它们的信号强度对放电电流的类似依赖性。这些结果表明,血浆中产生的分析物离子的传输过程在确定GDMS中的离子强度方面起着重要作用。