For establishing a method to diagnose the deterioration of ZnO surge arresters with a series gap of power distribution Systems, changes in leakage current of the arrester against the number of operation times were measured when the arrester was operated repeatedly at a large current of 10kA, 4/10μs. To clarify the cause for the changes, the surface of the spacer was observed using an electron probe micro analyzer and a x-ray photoelectron spectroscope after the arrester was operated repeatedly by a large current. Then, the optical emission of the impulse discharge plasma was investigated using a spectroscope with an optical multichannel analyzer. As the results show, it was found that the change in the leakage current of the arrester against the number of operation times was dominantly affected by change in contamination of the surface of the gap spacer which was caused by the metallic vapor emitted from the gap electrodes and transported by shock wave. This means that the deterioration of arresters can be diagnosed by measuring the leakage current and taking into consideration the tendencies in changes of leakage-current and sparkover-voltage changes of the arresters with respect to the number of operation times.
机译:为了建立一种诊断方法,以诊断带有一系列配电系统的ZnO电涌放电器的劣化,当在10kA的大电流下反复操作避雷器时,测量了避雷器的漏电流相对于操作次数的变化4 /10μs。为了弄清变化的原因,在大电流下反复操作避雷器之后,使用电子探针显微分析仪和X射线光电子能谱仪观察隔离物的表面。然后,使用带有光学多通道分析仪的分光镜研究脉冲放电等离子体的光发射。结果表明,避雷器的漏电流相对于操作次数的变化主要受到由间隙电极发射的金属蒸气引起的间隙隔离物表面的污染变化的影响。并通过冲击波运输。这意味着可以通过测量漏电流并考虑避雷器的漏电流和火花电压变化相对于操作次数的变化趋势来诊断避雷器的劣化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号