首页> 外文期刊>鋼構造論文集 >EVALUATION OF CORROSION AT CONTACT SURFACE ON GUSSET PLATE CONNECTIONS OF STEEL TRUSS BRIDGE
【24h】

EVALUATION OF CORROSION AT CONTACT SURFACE ON GUSSET PLATE CONNECTIONS OF STEEL TRUSS BRIDGE

机译:桁架桥拱衬板连接处接触表面的腐蚀评估

获取原文
获取原文并翻译 | 示例
           

摘要

Crevice corrosion between gusset plate connections and the flanges of diagonal members remains an unknown phenomenon. In this work, gusset plate connection, flanges of diagonal members and additional reinforcement plates were removed from a dismantled bridge for crevice corrosion measurements. The contact surfaces of two gusset plate connections, one standard upper connection and one lower connection with reinforcement, were measured in detail using laser equipment. From the results, the actual crevice corrosion state of these members were evaluated and graphs of corrosion depth distribution produced.
机译:角撑板连接和对角构件的法兰之间的缝隙腐蚀仍然是未知的现象。在这项工作中,从拆除的桥上卸下了角撑板连接,对角构件的法兰和附加的加固板,以进行缝隙腐蚀测量。使用激光设备详细测量了两个角撑板连接件,一个标准的上连接件和一个带加强件的下连接件的接触面。根据结果​​,评估了这些构件的实际缝隙腐蚀状态,并绘制了腐蚀深度分布图。