首页> 外文期刊>Journal of synchrotron radiation >A transparent two-dimensional in situ beamposition and profile monitor for synchrotron X-ray beamlines
【24h】

A transparent two-dimensional in situ beamposition and profile monitor for synchrotron X-ray beamlines

机译:用于同步加速器X射线束线的透明二维原位射线束定位和轮廓监测仪

获取原文
获取原文并翻译 | 示例
           

摘要

A compact, inexpensive and easy- to- construct two- dimensional in situ beam-position and profile monitor for synchrotron X- ray beamlines is presented. The device is based on the collection of spatially resolved scattered radiation from a polyimide foil. The X- ray beam passes through a foil placed in the path of the beam, which absorbs no more than 3% of the beam at 12 keV. The scattered radiation is collected at an angle of 90 degrees through a collimator located below the foil onto a CCD sensor. The device was tested on bending- magnet beamline BM26 at the ESRF synchrotron radiation source and has a positional sensitivity better than 10 mu m with a large working range of 25 mm x 25 mm. Although the device is optimized for use in the range 10 - 12 keV, it can easily be modified for use with higher- energy beams by using a suitably chosen scattering foil.
机译:提出了一种紧凑,便宜且易于构造的用于同步加速器X射线束线的二维原位射线位置和轮廓监测器。该设备基于从聚酰亚胺箔收集的空间分辨的散射辐射。 X射线束穿过放置在光束路径中的箔,该箔在12 keV时吸收的光束不超过3%。散射的辐射通过位于箔下方的准直仪以90度角收集到CCD传感器上。该设备在ESRF同步加速器辐射源的弯曲磁体光束线BM26上进行了测试,其位置灵敏度优于10μm,工作范围为25 mm x 25 mm。尽管该设备已针对10至12 keV的使用范围进行了优化,但可以通过使用适当选择的散射箔片轻松地对其进行修改,以用于更高能量的光束。