The use of polyacrylamide gels for mechanical calibration of cartilage--a combined nanoindentation and unconfined compression study.

机译:聚丙烯酰胺凝胶用于软骨的机械校准-纳米压痕和无侧限压制研究的组合。

获取原文
获取原文并翻译 | 示例
           

摘要

This study investigates polyacrylamide (PA) gel as a calibration material to measure the nanomechanical compressive modulus of cartilage using nanoindentation. Both nanoindentation and unconfined compression testing were performed on PA gel and porcine rib cartilage. The equilibrium moduli measured by the two methods were discernable. Nanoindentation has the advantage of distinguishing between spatially dependent constituent properties that affect tissue mechanical function in heterogeneous and hierarchically structured tissues such as cartilage. Both sets of measurements exhibited similar positive correlation with increasing gel crosslinker concentration. The compressive modulus measurements from compression in the PA gels ranged from 300 kPa-1.4 MPa, whereas those from nanoindentation ranged from 100 kPa-1.1 MPa. Using this data, a method for relating nanoindentation measurements to conventional mechanical property measurements is presented for porcine rib cartilage. It is shown that based on this relationship, the local tissue modulus as measured from nanoindentation (1.1-1.4 MPa) was able to predict the overall global modulus of the same sample of rib cartilage (2.2 MPa), as confirmed by experimental measurements from unconfined compression. This study supports the use of nanoindentation for the local characterization of cartilage tissues and may be applied to other soft tissues and constructs.
机译:这项研究调查聚丙烯酰胺(PA)凝胶作为校准材料,使用纳米压痕法测量软骨的纳米机械压缩模量。纳米压痕和无侧限压缩测试均在PA凝胶和猪肋软骨上进行。通过两种方法测得的平衡模量是可辨别的。纳米压痕的优势在于可以区分影响软骨等异质组织和层次结构组织中的机械功能的空间依赖性成分特性。两组测量结果均显示出与凝胶交联剂浓度增加相关的相似正相关性。在PA凝胶中压缩产生的压缩模量范围为300 kPa-1.4 MPa,而纳米压痕测量的压缩模量范围为100 kPa-1.1 MPa。使用该数据,提出了一种将纳米压痕测量与常规机械性能测量相关的方法,用于猪肋软骨。结果表明,基于这种关系,纳米压痕测量的局部组织模量(1.1-1.4 MPa)能够预测同一肋骨软骨样品(2.2 MPa)的整体总体模量,如无限制的实验测量结果所证实压缩。这项研究支持使用纳米压痕技术对软骨组织进行局部表征,并可以应用于其他软组织和构建体。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号