A quantitative procedure based on the magnetic flux leakage technique was proposed to evaluate the size of metal-loss type flaws such as corrosion pits in oil storage tank bottom floors.The approach considers both experimental findings and theoretical modeling of the simplified model flaws of local corrosion or pitting.Experiments were carried out on steel plate specimens,which contained artificial flaws with various depths and widths,such as flat-bottomed cylindrical holes and rectangular grooves in the backside of the specimen plates.The experimental results suggested that the depth of the flaw or residual plate thickness could be estimated by measurements of the strength and distribution of the vertical component of the magnetic leakage flux density,which is affected by far-side flaws.Analytical model calculations confirmed these findings.Moreover,a practical evaluation procedure for sizing flaws or the residual thickness of metal loss area by this technique are developed.The far-side magnetic leakage flux density distributions for conical holes were also measured and calculated using the theoretical model to confirm the procedure,which corrects the amplitude of the calculated far-side magnetic leakage flux density distribution.The far-side magnetic leakage flux density distributions for conical holes could be reproduced using the procedure.
机译:提出了一种基于漏磁技术的定量程序来评估储油罐底部底板等金属损耗型缺陷的尺寸,该方法同时考虑了实验结果和简化局部腐蚀模型缺陷的理论模型对含有不同深度和宽度的人造缺陷的钢板试样进行了实验,例如试样板背面的平底圆柱孔和矩形凹槽。实验结果表明该缺陷的深度可以通过测量漏磁通密度的垂直分量的强度和分布来估计钢板的残余厚度或厚度,该强度和分布受远端缺陷的影响。分析模型计算证实了这些发现。此外,一种实用的缺陷尺寸评估程序或通过这种技术来开发金属损失区域的剩余厚度。还通过理论模型测量并计算了锥形孔的去磁通量密度分布,以确认该程序,从而校正了计算出的远侧漏磁通量密度分布的幅度。可以使用该程序复制孔。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号