We have studied the issues associated with the use of platinum electrodes for transdermal iontophoretic delivery of peptides, using insulin as a model peptide. Insulin permeation was studied using full-thickness rat skin by varying the donor solution pH as a function of electrode polarity. The stability of insulin under the iontophoretic conditions was studied using TLC, SDS-polyacrylamide gel electrophoresis and HPLC. Large pH shifts were observed during anodal iontophoresis (AI), when the donor solution pH was above the isoelectric point of insulin and in cathodal iontophoresis (CI), when the donor solution pH was below the isoelectric point of insulin. The direction and magnitude of electroosmotic flow was influenced by pH of the donor solution and the electrode polarity. On the other hand, the buffer used to maintain the pH governed the contribution of electrorepulsion to the overall transport of insulin. Electrochemical degradation of insulin was significant during AI at pH 7.4. Among the pH investigated, AI of insulin at pH 3.6 and CI at pH 8.35 were better, as the pH shift was relatively less and electrochemically more stable during iontophoresis as compared with other pH. In summary, the pH shift caused by platinum electrodes had a significant influence on the permeation and stability of insulin.
机译:我们已经研究了使用胰岛素作为模型肽,将铂电极用于肽的透皮离子电渗传递的相关问题。使用全厚度大鼠皮肤通过改变供体溶液的pH值作为电极极性的函数来研究胰岛素的渗透性。使用TLC,SDS-聚丙烯酰胺凝胶电泳和HPLC研究了离子电渗条件下胰岛素的稳定性。当供体溶液的pH值高于胰岛素的等电点时,在阳极离子电渗疗法(AI)期间观察到较大的pH值变化;当供体溶液的pH值低于胰岛素的等电点时,在阴极离子电渗疗法(CI)中观察到。电渗流的方向和大小受供体溶液的pH和电极极性的影响。另一方面,用于维持pH值的缓冲液控制着电排斥对胰岛素整体转运的作用。在AI的pH值为7.4期间,胰岛素的电化学降解作用显着。在研究的pH值中,与其他pH值相比,在离子电渗疗法中pH值变化相对较小并且电化学上更稳定,因此在pH 3.6时胰岛素的AI和在pH 8.35时的CI更好。总之,由铂电极引起的pH值变化对胰岛素的渗透和稳定性有重要影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号