Long-term vessel response to a self-expanding coronary stent: a serial volumetric intravascular ultrasound analysis from the ASSURE Trial.A Stent vs. Stent Ultrasound Remodeling Evaluation.

机译:自扩张冠状动脉支架的长期血管反应:ASSURE试验进行的连续容积血管内超声分析,支架与支架超声重塑评估。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVES: We sought to investigate the in vivo mechanical properties of a new self-expanding coronary stent (RADIUS) and, particularly, the subsequent vessel response over time. BACKGROUND: Preclinical studies have suggested that self-expanding stents may produce less vessel wall injury at initial deployment, leading to larger follow-up lumens than with balloon-expandable stents. However, the influence of the chronic stimulus from self-expanding stents on the vessel wall remains unknown. METHODS: Sixty-two patients were randomly assigned to either the RADIUS self-expanding stent group (n = 32) or the Palmaz-Schatz balloon-expandable stent group (n = 30). Intravascular ultrasound was performed after stent deployment and at six-month follow-up. RESULTS: At follow-up, the RADIUS stents had increased 23.6% in overall volume, while the Palmaz-Schatz stents had remained unchanged. Due to the greater mean neointimal area (3.0 +/- 1.7 mm2 vs. 1.9 +/- 1.2 mm2, p = 0.02) in the RADIUS group, no significant difference in net late lumen loss was observed between the two groups. On the other hand, analysis at the peristent margins demonstrated that mean late loss was significantly smaller in the RADIUS group than it was in the Palmaz-Schatz group (0.1 +/- 2.1 mm2 vs. 1.9 +/- 2.4 mm2, p = 0.02). CONCLUSIONS: Serial volumetric IVUS revealed that the RADIUS stents continued to enlarge during the follow-up period. In this stent implantation protocol, this expansion was accompanied by a greater amount of neointima than the Palmaz-Schatz stents, resulting in similar late lumen loss in both configurations. In the peristent margins, however, late lumen loss was minimized with the RADIUS stents.
机译:目的:我们试图研究一种新的自膨胀冠状动脉支架(RADIUS)的体内力学性能,尤其是随着时间的推移随后的血管反应。背景:临床前研究表明,自扩张式支架在初始部署时可产生较少的血管壁损伤,与气囊扩张式支架相比,导致更大的随访腔。然而,来自自扩张支架的慢性刺激对血管壁的影响仍然未知。方法:62例患者被随机分为RADIUS自扩张支架组(n = 32)或Palmaz-Schatz球囊扩张支架组(n = 30)。在支架展开后和六个月的随访中进行血管内超声检查。结果:在随访中,RADIUS支架的总体积增加了23.6%,而Palmaz-Schatz支架则保持不变。由于RADIUS组的平均新内膜面积更大(3.0 +/- 1.7 mm2 vs. 1.9 +/- 1.2 mm2,p = 0.02),因此两组之间的净晚期管腔损失没有显着差异。另一方面,以固定边际进行的分析表明,RADIUS组的平均延迟损失明显小于Palmaz-Schatz组(0.1 +/- 2.1平方毫米与1.9 +/- 2.4平方毫米,p = 0.02)。 )。结论:连续体积IVUS显示在随访期间RADIUS支架持续扩大。在这种支架植入方案中,与Palmaz-Schatz支架相比,这种扩张伴随着更多的新内膜,导致两种配置中相似的晚期管腔丢失。然而,在永久边缘,使用RADIUS支架可使晚期管腔损失最小化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号