首页> 外文期刊>Journal of separation science. >Development and validation of a direct headspace GC-FID method for the determination of sevoflurane, desflurane and other volatile compounds of forensic interest in biological fluids: Application on clinical and post-mortem samples
【24h】

Development and validation of a direct headspace GC-FID method for the determination of sevoflurane, desflurane and other volatile compounds of forensic interest in biological fluids: Application on clinical and post-mortem samples

机译:一种直接顶空GC-FID方法的开发和验证,该方法用于确定生物流体中具有法医学意义的七氟醚,地氟醚和其他挥发性化合物:在临床和验尸样品中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

A simple and reliable headspace GC-flame ionization detection (HS-GC-FID) method has been developed and validated for the simultaneous determination of seven volatile compounds of forensic interest: sevoflurane, desflurane, ethanol, methanol, 1-propanol, acetone and acetaldehyde. All seven compounds including acetonitrile (internal standard) eluted within 10 min and were well resolved with no endogenous interference. Good linearity was observed in the range of 1-12 mg/dL for both anesthetics and 2.5-40 mg/dL for the other five analytes. The method showed good precision, sensitivity and repeatability. Most of the analytes remained stable during the storage of samples at 4°C. Desflurane and acetone degraded (>10%), when the samples remained on the autosampler for more than 2 and 3 h, respectively. The method was finally applied on clinical and post-mortem blood and urine samples. The clinical samples were collected both from patients who underwent surgery, as well as from the occupationally exposed medical and nursing staff of the university hospital, working in the operating rooms. The hospital staff samples were found negative for all compounds, while the patients' samples were found positive for the anesthetic administered to the patient. The post-mortem blood samples were found positive for ethanol and acetaldehyde.
机译:已开发出一种简单可靠的顶空GC火焰电离检测(HS-GC-FID)方法,并已验证该方法可同时测定法医相关的七种挥发性化合物:七氟醚,地氟醚,乙醇,甲醇,1-丙醇,丙酮和乙醛。包括乙腈(内标)在内的所有七种化合物均在10分钟内被洗脱,并且得到良好分离,没有内源干扰。麻醉剂均在1-12 mg / dL范围内,其他五种分析物在2.5-40 mg / dL范围内观察到良好的线性。该方法具有良好的精密度,灵敏度和可重复性。在4°C下保存样品期间,大多数分析物保持稳定。当样品分别在自动进样器上停留2小时和3小时以上时,地氟醚和丙酮会降解(> 10%)。该方法最终应用于临床和验尸后的血液和尿液样本。从接受手术的患者以及在手术室工作的大学医院职业暴露的医护人员中收集临床样品。医院工作人员的所有化合物均为阴性,而患者的麻醉剂为阳性。验尸后的血液样本中发现乙醇和乙醛呈阳性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号