...
首页> 外文期刊>Journal of refractive surgery >Correlation of visual performance with quality of life and intraocular aberrometric profile in patients implanted with rotationally asymmetric multifocal IOLs
【24h】

Correlation of visual performance with quality of life and intraocular aberrometric profile in patients implanted with rotationally asymmetric multifocal IOLs

机译:植入旋转不对称多焦点人工晶体的患者的视觉性能与生活质量和眼内像差图的相关性

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To examine the visual performance of a rotationally asymmetric multifocal intraocular lens (IOL) by correlating the defocus curve of the IOL-implanted eye with the intraocular aberrometric profile and impact on the quality of life. METHODS: A prospective, consecutive, case series study including 26 eyes from 13 patients aged between 50 and 83 years (mean: 65.54±7.59 years) was conducted. All patients underwent bilateral cataract surgery with implantation of a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 MF30, Oculentis GmbH). Distance and near visual acuity outcomes, intraocular aberrations, defocus curve, and quality of life (assessed using the National Eye Institute Visual Functioning Questionnaire-25) were evaluated postoperatively (mean follow-up: 6.42±2.24 months). RESULTS: A significant improvement in distance visual acuity was found postoperatively (P<.01). Mean postoperative logMAR distance-corrected near visual acuity was 0.19±0.12 (~20/30). Corrected distance visual acuity and near visual acuity of 20/20 or better were achieved by 30.8% and 7.7% of eyes, respectively. Of all eyes, 96.2% had a postoperative addition between 0 and 1.00 diopter (D). The defocus curve showed two peaks of maximum visual acuity (0 and 3.00 D of defocus), with an acceptable range of intermediate vision. LogMAR visual acuity corresponding to near defocus was directly correlated with some higher order intraocular aberrations (r≥0.44, P≤.04). Some difficulties evaluated with the quality of life test correlated directly with near and intermediate visual acuity (r≥0.50, P≤.01). CONCLUSIONS: The Lentis Mplus multifocal IOL provides good distance, intermediate, and near visual outcomes; however, the induced intraocular aberrometric profile may limit the potential visual benefit.
机译:目的:通过将人工晶状体植入的眼睛的散焦曲线与眼内像差图相关联并影响生活质量,来检查旋转不对称多焦点人工晶状体(IOL)的视觉性能。方法:进行了一项前瞻性,连续病例系列研究,研究对象为年龄在50至83岁(平均65.54±7.59岁)的13例患者的26只眼睛。所有患者均进行了植入旋转不对称多焦点IOL的双侧白内障手术(Lentis Mplus LS-312 MF30,Oculentis GmbH)。术后评估远近视力结果,眼内像差,散焦曲线和生活质量(使用美国国家眼科学院视觉功能问卷-25评估)(平均随访时间:6.42±2.24个月)。结果:术后远视力明显改善(P <.01)。术后平均logMAR距离校正后的近视力为0.19±0.12(〜20/30)。分别有30.8%和7.7%的眼睛可获得20/20或更高的矫正远视力和近视力。在所有眼睛中,有96.2%的患者术后屈光度在0到1.00之间(D)。散焦曲线显示了最大视敏度的两个峰值(散焦为0和3.00 D),具有中等范围的可接受范围。与近散焦相对应的LogMAR视敏度与一些较高阶的眼内像差直接相关(r≥0.44,P≤.04)。生活质量测试评估的一些困难与中,近视力直接相关(r≥0.50,P≤.01)。结论:Lentis Mplus多焦点IOL可提供良好的远距离,中距离和近距离视觉效果。但是,诱发的眼内像差图可能会限制潜在的视觉益处。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号