首页> 外文期刊>Journal of liquid chromatography and related technologies >An alternative method for determination of additives in polypropylene using supercritical fluid extraction and enhanced solvent extraction
【24h】

An alternative method for determination of additives in polypropylene using supercritical fluid extraction and enhanced solvent extraction

机译:使用超临界流体萃取和增强溶剂萃取法测定聚丙烯中添加剂的另一种方法

获取原文
获取原文并翻译 | 示例
           

摘要

The extraction of Irganox 1076, Irgafos 168, and Irganox 1010 from polypropylene (PP) by supercritical fluid extraction (SFE) and enhanced fluid extraction (ESE) was investigated to find an alternative method to the dissolution extraction required by regulators for polymers used for the packaging of liquid pharmaceutical formulations. The maximum recovery with SFE was obtained at a CO2 pressure of 680 bar at a temperature of 100 degrees C, with 10% methanol as modifier and static and dynamic extraction times of 30 and 40 minutes, respectively. This gave a recovery of >= 95% for Irganox 1076 and Irgafos 168 compared to the pharmacopoeial method, and a recovery of 62% for Irganox 1010. With ESE, the maximum extraction was obtained at a temperature of 100 degrees C, a restrictor flow rate of 5mL/min, a static extraction time of 90 minutes, and a solvent mixture of 2-propanol-cyclohexane (75: 25 v/v). The recoveries for Irganox 1076 and Irgafos 168 were 109% and 121%, respectively, compared to the pharmacopoeial method, while the recovery for Irganox 1010 was 86%. When a higher temperature was used with ESE, the recoveries of Irganox 1076 and Irgafos 168 were unchanged but that of Irganox 1010 increased to 96%. Unfortunately, at the higher temperature, the PP partly melted and caused a system blockage. A better recovery than 86% of Irganox 1010 is required for a method to be an alternative to the dissolution extraction method.
机译:研究了通过超临界流体萃取(SFE)和增强流体萃取(ESE)从聚丙烯(PP)中萃取Irganox 1076,Irgafos 168和Irganox 1010的方法,以寻找调节剂所需的溶出萃取的替代方法,该调节剂用于聚合物。液体药物制剂的包装。 SFE的最大回收率是在100 bar的温度下,680 bar的CO2压力下,使用10%甲醇作为改性剂,静态和动态萃取时间分别为30分钟和40分钟。与药典方法相比,Irganox 1076和Irgafos 168的回收率为> = 95%,Irganox 1010的回收率为62%。使用ESE,在100摄氏度的温度下(限流器)可获得最大萃取率流速为5mL / min,静态萃取时间为90分钟,并使用2-丙醇-环己烷的混合溶剂(75:25 v / v)。与药典方法相比,Irganox 1076和Irgafos 168的回收率分别为109%和121%,而Irganox 1010的回收率为86%。当ESE使用更高的温度时,Irganox 1076和Irgafos 168的回收率保持不变,但Irganox 1010的回收率增加到96%。不幸的是,在较高的温度下,PP部分熔化并导致系统堵塞。该方法需要比86%的Irganox 1010更好的回收率,才能替代溶出萃取方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号