Objective:To determine whether an electronic data surveillance system, or Data Sniffer (DS), could reduce the rate of hyperoxic episodes (HEs) among premature neonates being managed by a standardized respiratory treatment protocol (RTP).Study Design:A total of 86 infants born at <29 weeks of gestation were included in the study. The rates of HEs were compared among four epochs (E) as follows: E1: no RTP, no DS; E2:with RTP, no DS; E3: with RTP, with DS; E4: with RTP, no DS.Result:After implementing the RTP in E2, the rate of HEs was 44% lower than that of E1. Activating the DS in E3 further reduced HEs by 26%, whereas its deactivation in E4 resulted in a rebound in HEs to baseline rates; P<0.0001 for each comparison.Conclusion:The implementation of an electronic data monitoring system was associated with less frequent episodes of hyperoxia among premature neonates.
机译:目的:确定电子数据监视系统或数据嗅探器(DS)是否可以降低通过标准化呼吸治疗协议(RTP)管理的早产儿的高氧发作(HE)发生率。研究设计:总共86个妊娠<29周出生的婴儿包括在研究中。比较四个时期(E)的HE率:E1:无RTP,无DS; E2:带RTP,无DS; E3:具有RTP,具有DS; E4:具有RTP,无DS。结果:在E2中实施RTP后,HE的发生率比E1低44%。激活E3中的DS进一步将HE降低了26%,而E4中的DS失活导致了HE反弹至基线速率;每次比较P <0.0001。结论:电子数据监测系统的实施与早产儿高氧血症发作频率较低相关。