【24h】

Fetal bone strength and umbilical cord length.

机译:胎儿骨强度和脐带长度。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVE: Activity has been demonstrated in promoting bone mass in infants and adults. One of the major signs of fetal activity may be the length of the umbilical cord. We hypothesized that the fetus with a shortened umbilical cord may have low bone mineralization because of decreased movement or activity. STUDY DESIGN: We investigated eight healthy term infants with shortened umbilical cords and 15 control term infants. Mothers with pre-eclampsia or hypertension, chorioamnionitis or prolonged ruptured of membranes were excluded from the study. Mother's age, parity, infants' gender, and birth and placenta weights were recorded. The umbilical cord length and diameter were measured as well as the newborn's tibial speed of sound (SOS). SOS measurements (Sunlight Omnisense 7000P instrument) were obtained at the tibial midshaft. RESULTS: Measurement reproducibility was 0.8+/-0.6% (mean+/-s.d.) for repeat SOS measures. There were no differences between the two groups in mother's age (24.6+/-5.8 vs 25.8+/-3.3 years), parity (2+/-1 vs 2+/-1), infant's gender (25% females vs 47% females), birth weights (3320+/-451 vs 3409+/-452 g), or placental weights (521+/-69 vs 588+/-105 g). Umbilical cord diameters were also similar, 1.1+/-0.3 vs 1.1+/-0.2 cm. However, there was a difference in the cord length between the two groups, 46+/-2 vs 57+/-4 cm (Mann-Whitney, P<0.001). The newborn infants with the shorter umbilical cord also had lower tibial SOS compared with controls, 3047+/-107 vs 3194+/-311 m/sec (Mann-Whitney, P<0.05). Tibial SOS was related to the infant's umbilical cord length (r=0.57, P<0.01) but not to infant's birth weight, gender, umbilical cord diameter, maternal age, or placenta weight. CONCLUSION: Infants with a short umbilical cord length have lower bone strength.
机译:目的:已证明活性可促进婴儿和成人的骨量。胎儿活动的主要标志之一可能是脐带的长度。我们假设脐带缩短的胎儿可能由于运动或活动减少而骨矿化程度低。研究设计:我们调查了8名脐带缩短的健康足月婴儿和15名对照足月婴儿。患有先兆子痫或高血压,绒毛膜羊膜炎或长时间胎膜破裂的母亲被排除在研究之外。记录母亲的年龄,胎次,婴儿的性别以及出生和胎盘的重量。测量了脐带的长度和直径,以及新生儿的胫骨声速(SOS)。在胫骨中轴获得SOS测量值(Sunlight Omnisense 7000P仪器)。结果:重复SOS测量的测量重现性为0.8 +/- 0.6%(平均+/- s.d。)。两组的母亲年龄(24.6 +/- 5.8 vs 25.8 +/- 3.3岁),胎次(2 +/- 1 vs 2 +/- 1),婴儿性别(25%的女性和47%的女性)没有差异。女性),出生体重(3320 +/- 451 vs 3409 +/- 452 g)或胎盘重量(521 +/- 69 vs 588 +/- 105 g)。脐带直径也相似,分别为1.1 +/- 0.3和1.1 +/- 0.2 cm。然而,两组之间的脐带长度有所不同,分别为46 +/- 2与57 +/- 4 cm(Mann-Whitney,P <0.001)。与对照组相比,脐带较短的新生儿的胫骨SOS也较低,分别为3047 +/- 107和3194 +/- 311 m / sec(Mann-Whitney,P <0.05)。胫骨SOS与婴儿的脐带长度有关(r = 0.57,P <0.01),与婴儿的出生体重,性别,脐带直径,产妇年龄或胎盘重量无关。结论:脐带长度短的婴儿的骨强度较低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号