首页> 外文期刊>Journal of Pharmaceutical and Biomedical Analysis: An International Journal on All Drug-Related Topics in Pharmaceutical, Biomedical and Clinical Analysis >Extraction spectrophotometric determination of aluminum in dialysis concentrates with 3,5-ditertbutylsalicylfluorone and ionic liquid 1-butyl-3-trimethylsilylimidazolium hexafluorophosphate.
【24h】

Extraction spectrophotometric determination of aluminum in dialysis concentrates with 3,5-ditertbutylsalicylfluorone and ionic liquid 1-butyl-3-trimethylsilylimidazolium hexafluorophosphate.

机译:3,5-二叔丁基水杨基芴酮和离子液体1-丁基-3-三甲基甲硅烷基咪唑六氟磷酸盐的萃取光度法测定浓缩液中的铝。

获取原文
获取原文并翻译 | 示例
           

摘要

The paper describes a highly sensitive and selective extraction spectrophotometric method for determination of aluminum in dialysis concentrates with new reagent 3,5-ditertbutylsalicylfluorone abbreviated as DTBSF, in which the ionic liquid 1-butyl-3-trimethylsilylimidazolium hexafluorophosphate abbreviated as [C4tmsim][PF6] was used as novel medium for liquid/liquid extraction of aluminum(III). Under optimal condition, DTBSF reacted with aluminum(III) to form a neutral Al-DTBSF complex rapidly, the complex was then extracted into the [C4tmsim][PF6] phase, the absorbance of the complex in ionic liquid at 542 nm was recorded and used to determine aluminum(III). The apparent molar absorptivity of the complex and detection limit were found to be 3.52x10(6) l mol(-1) cm(-1) and 0.06 microg/l, respectively. The absorbance of the complex at 542 nm increases linearly with the concentration of aluminum(III) up to 3 microg of aluminum(III) in 250 ml of aqueous solution. The interference study show the determination of aluminum is free from interferences of almost all positive and negative ions found in dialysis concentrate samples. The determination of aluminum in dialysis concentrates were carried out by the present method and electrothermal atomic absorption spectrometry (GTAAS). The results were satisfactorily comparable so that the applicability of the proposed method with the ionic liquid system was also investigated. Moreover, the synthesis of and conditions for the formation and extraction of Al-DTBSF complex were investigated as well.
机译:本文介绍了一种高灵敏度的选择性萃取光度法,该方法使用新试剂3,5-二叔丁基水杨基氟酮(缩写为DTBSF)测定透析浓缩液中的铝,其中离子液体1-丁基-3-三甲基甲硅烷基咪唑六氟磷酸盐缩写为[C4tmsim] [PF6用作新的介质,用于液/液萃取铝(III)。在最佳条件下,DTBSF与铝(III)反应迅速形成中性Al-DTBSF络合物,然后将络合物萃取到[C4tmsim] [PF6]相中,记录该络合物在542 nm离子液体中的吸光度,用于测定铝(III)。该复合物的表观摩尔吸收率和检测极限分别为3.52x10(6)l mol(-1)cm(-1)和0.06 microg / l。在250 ml水溶液中,络合物在542 nm处的吸光度随铝(III)的浓度线性增加,最高可达3微克铝(III)。干扰研究表明,铝的测定不受浓缩透析液样品中几乎所有正离子和负离子的干扰。通过本方法和电热原子吸收光谱法(GTAAS)进行透析浓缩液中铝的测定。结果令人满意地具有可比性,因此还研究了该方法在离子液体体系中的适用性。此外,还研究了Al-DTBSF配合物的合成及其形成和提取的条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号