...
首页> 外文期刊>Journal of Pharmaceutical and Biomedical Analysis: An International Journal on All Drug-Related Topics in Pharmaceutical, Biomedical and Clinical Analysis >Effect of creatinine and specific gravity normalization techniques on xenobiotic biomarkers in smokers' spot and 24-h urines.
【24h】

Effect of creatinine and specific gravity normalization techniques on xenobiotic biomarkers in smokers' spot and 24-h urines.

机译:肌酐和比重归一化技术对吸烟者点尿和24小时尿液中异种生物标志物的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

Renal excretion mechanisms are xenobiotic-specific; therefore, accurate exposure assessment requires an understanding of relationships of xenobiotic biomarker concentration and excretion rate to urine flow, specific gravity and creatinine concentration. Twenty-four-hour urine collection for xenobiotic exposure assessment is considered the "gold standard" procedure. Random spot-urine collection is convenient and minimizes subject compliance concerns but requires that normalization techniques be employed to account for diuresis and diurnal variation in xenobiotic biomarker excretion. This paper examines and makes recommendations concerning normalization techniques and conditions under which spot-urine results most accurately reflect 24-h urine results. Specific gravity, creatinine, and xenobiotic biomarkers were determined in smokers' spot and 24-h urines. Normalization techniques were applied, variance-component analyses were performed to estimate variability, spot urines were pooled mathematically to simulate 24-h urines and analyses of variance were performed to evaluate spot urines' ability to reflect 24-h urine concentrations. For each xenobiotic biomarker concentration, log-linear relationships were observed with urine flow, specific gravity, and creatinine. For most xenobiotic biomarker excretion rates, log-linear relationships were observed with urine flow; creatinine, however, was unaffected by urine flow. The conventional creatinine ratio-normalization technique demonstrated greater variability (within-day, between-day and between-subject) than other normalization techniques. Comparisons of simulated 24-h urines to spot urines suggest that spot-urine collection be performed only between 2 p.m. and 2 a.m. and that the modified specific-gravity-adjusted-creatinine ratio-normalization technique and the creatinine-regression normalization technique yield the best agreement between spot- and simulated 24-h urine results.
机译:肾脏排泄机制是异种生物特异的。因此,准确的暴露评估需要了解异生物素生物标志物浓度和排泄率与尿流,比重和肌酐浓度之间的关系。用于异物接触评估的二十四小时尿液收集被认为是“黄金标准”程序。随机收集尿液很方便,可以最大程度地减少受试者的依从性,但需要使用归一化技术来解决异生物素生物标志物排泄中的利尿和昼夜变化。本文研究并提出了有关归一化技术和条件的建议,在这些技术和条件下,点尿结果最准确地反映了24小时尿液结果。在吸烟者的现场和24小时尿液中确定了比重,肌酐和异生物素生物标志物。应用归一化技术,进行方差成分分析以估计变异性,将现场尿液进行数学合并以模拟24小时尿液,并进行方差分析以评估现场尿液反映24小时尿液浓度的能力。对于每种异生物素生物标志物浓度,观察到与尿流量,比重和肌酐的对数线性关系。对于大多数异源生物标志物的排泄率,观察到与尿流的对数线性关系。然而,肌酐不受尿流的影响。常规肌酐比率归一化技术显示出比其他归一化技术更大的可变性(日内,日间和受试者间)。将模拟的24小时尿液与尿液进行比较表明,尿液收集仅在下午2点之间进行。和凌晨2点,修改后的比重调整肌酐比率归一化技术和肌酐回归归一化技术在点尿和模拟24小时尿液结果之间取得了最佳一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号