...
【24h】

13C/12C isotope ratio MS analysis of testosterone, in chemicals and pharmaceutical preparations.

机译:化学品和药物制剂中睾丸激素的13C / 12C同位素比MS分析。

获取原文
获取原文并翻译 | 示例
           

摘要

The 13C/12C ratio can be used to detect testosterone misuse in sport because (semi)-synthetic testosterone is supposed to have a 13C abundance different from that of endogenous natural human testosterone. In this study, gas chromatography/combustion isotope ratio mass spectrometry (GC/C/IRMS) analysis for the measurement of the delta 13C/1000 value of testosterone from esterified forms of 13 pharmaceutical preparations, six reagent grade chemicals and three bulk materials (raw materials used in pharmaceutical proarations) obtained world-wide was investigated after applying a strong acidic solvolytic procedure. Mean delta 13C/1000 values of non esterified (free) testosterone from chemicals and bulk materials of several testosterone esters were in the range: -25.91/-32.82/1000 while the value obtained for a (semi)-synthetic, reagent grade, free testosterone was -27.36/1000. The delta 13C/1000 results obtained for testosterone from the pharmaceuticals investigated containing testosterone esters were quite homogeneous (mean and S.D. of delta 13C/1000 values of free testosterone: 27.43 +/- 0.76/1000), being the range between -26.18 and -30.04/1000. Values described above were clearly different from those reported by several authors for endogenous natural human testosterone and its main metabolites excreted into the urine in non-consumers of testosterone (delta 13C/1000 range: from -21.3 to -24.4/1000), while they were similar to those of urinary testosterone and metabolites from individuals treated with testosterone esters and testosterone precursors. This finding justifies the fact that administration of these pharmaceutical formulations led to a statistical decrease of carbon isotope ratio of urinary testosterone and its main metabolites in treated subjects.
机译:13C / 12C比率可用于检测运动中的睾丸激素滥用,因为(半)合成睾丸激素的13C丰度应该与内源性天然人类睾丸激素的丰度不同。在这项研究中,气相色谱/燃烧同位素比质谱(GC / C / IRMS)分析用于测量13种药物制剂,6种试剂级化学品和3种散装原料(原料)的酯化形式的睾丸激素的δ13C / 1000值。在应用强酸性溶剂分解工艺后,对在全球范围内获得的用于制药的材料进行了研究。来自化学品和几种睾丸激素酯的散装材料的未酯化(游离)睾丸激素的平均δ13C / 1000值范围为:-25.91 / -32.82 / 1000,而(半)合成试剂级游离睾丸激素为-27.36 / 1000。从所研究的含有睾丸激素酯的药物获得的睾丸激素的δ13C / 1000结果相当均匀(游离睾丸激素的δ13C / 1000平均值和标准偏差:27.43 +/- 0.76 / 1000),在-26.18和-之间30.04 / 1000。上述值明显不同于几位作者报道的内源性天然人类睾丸激素及其主要代谢产物在非消费者睾丸激素中排泄到尿中的值(δ13C / 1000范围:-21.3至-24.4 / 1000),而与使用睾丸激素酯和睾丸激素前体治疗的个体的尿中睾丸激素和代谢产物相似。该发现证明了以下事实:在治疗的受试者中,施用这些药物制剂导致尿中睾丸激素及其主要代谢产物的碳同位素比在统计上降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号