首页> 外文期刊>Journal of orthopaedic research >Functional sensibility assessment. Part I: develop a reliable apparatus to assess momentary pinch force control.
【24h】

Functional sensibility assessment. Part I: develop a reliable apparatus to assess momentary pinch force control.

机译:功能敏感性评估。第一部分:开发一种可靠的装置来评估瞬时捏力控制。

获取原文
获取原文并翻译 | 示例
           

摘要

A precise magnitude and timing control of pinch performance is based on accurate feed-forward and feedback control mechanisms. Ratio of peak pinch force and maximum load force during a functional performance is a sensitive parameter to reflect the ability to scale pinch force output according to actual loads. A pinch apparatus was constructed to detect momentary pinch force modulation of 20 subjects with normal hand sensation. The results indicated high intra-class correlation coefficient and small coefficient of variation of the detected force ratio among three repeated tests, which represented that the stability test of the measured response confirmed the feasibility of this apparatus. The force ratio for a 480 g object with a steel surface ranged between 1.77 and 1.98. Normal subjects were able to scale and contribute pinch force precisely to a pinch-holding-up test. This study may provide clinicians a reliable apparatus and method to analyze the recovery of functional sensibility in patients with nerve injuries.
机译:精确的捏合性能幅度和时序控制基于精确的前馈和反馈控制机制。在功能执行过程中,最大挤压力与最大挤压力之比是一个敏感参数,可反映根据实际负载缩放挤压力输出的能力。构造了一种收缩装置,以检测具有正常手感的20名受试者的瞬时收缩力调制。结果表明,在三个重复试验中,组内相关系数较高,而测得力比的变化系数较小,这表明所测响应的稳定性试验证实了该装置的可行性。 480 g物体在钢表面上的力比在1.77和1.98之间。正常受试者能够精确缩放并施加捏力,以进行捏捏测试。这项研究可以为临床医生提供可靠的设备和方法,以分析神经损伤患者的功能敏感性的恢复情况。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号