The objective of the study was to determine the biomechanical effect during insertion of multilevel hex-head design pedicle screws compared to a conventional screw-head design. Eighteen lumbar vertebrae and thoracic vertebrae from human cadavers were instrumented with a novel, multilevel hexagonal head pedicle screw on one side and a conventional head pedicle screw on the contralateral side. Screws were inserted at a constant rate and insertion and removal torques were recorded. A further 14 lumbar and thoracic vertebrae were used to test alterability of screw direction and operational effort required. Electromagnetic sensors recorded the change in angular direction for both screw and screwdriver. The force applied through the insertion screwdriver required to produce the directional change was also recorded. No significant differences were found between the two screw types for insertion or removal torque in either lumbar or thoracic vertebrae. Multilevel hex-head screws had significantly greater directional alterability than conventional head screws in both lumbar and thoracic specimens. Multilevel hex-head screws also required less force applied through the screwdriver than conventional screws to alter direction of screw insertion in both lumbar and thoracic specimens. The multilevel hex-head design did not affect the insertion or removal torque in comparison to a conventional head design.
机译:该研究的目的是确定与常规螺钉头设计相比,在插入多层六角头设计椎弓根螺钉期间的生物力学作用。取自人尸体的18个腰椎和胸椎,一侧分别装有新型多层六角头椎弓根螺钉,对侧一侧有常规头椎弓根螺钉。以恒定的速率插入螺钉,并记录插入和移除扭矩。使用另外的14个腰椎和胸椎来测试螺钉方向的变化和所需的操作强度。电磁传感器记录了螺丝和螺丝刀在角度方向上的变化。还记录了通过插入螺丝刀施加的产生方向变化所需的力。腰椎或胸椎的两种螺钉在插入或拔出扭矩方面均未发现明显差异。在腰椎和胸椎标本中,多层六角头螺钉的方向可变性都比常规头螺钉大得多。与传统的螺钉相比,多级六角头螺钉通过螺丝起子施加的力较小,从而可以改变腰椎和胸部标本的螺钉插入方向。与传统的头部设计相比,多层六角头设计不影响插入或移除扭矩。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号