首页> 外文期刊>Journal of occupational and environmental hygiene >Evaluation of the benefit of the user seal check on N95 filtering facepiece respirator fit.
【24h】

Evaluation of the benefit of the user seal check on N95 filtering facepiece respirator fit.

机译:评估用户对N95过滤式面罩呼吸器的密封性进行检查的益处。

获取原文
获取原文并翻译 | 示例
           

摘要

The objective of this study was to better understand the benefit of the user seal check step for respirator test subjects in the N95 filtering facepiece respirator donning process. To qualify for the study, subjects were required to pass a standard quantitative fit test on at least one of the three N95 filtering facepiece respirator models: 3M 1860 (cup), 3M 1870 (flat-fold), and Kimberly Clark PFR95-270 (duckbill). Eleven subjects were enrolled and performed a series of abbreviated, quantitative fit tests where they were randomly asked either to perform or not perform a user seal check with 20 different respirator samples of each model. The experimental design included 3 respirator models × 10 subjects × 2 treatment levels with 10 replications. Geometric mean (GM) fit factors and percentages of times a fit factor ≥ 100 was achieved for a donning were compared for each subject with and without the user seal check across all models and for each model. Higher GM fit factors and smaller geometric standard deviations across all models were achieved for 10 of the 11 subjects when performing a user seal check compared with not performing a user seal check. Geometric mean fit factors of 148, 184, and 156, compared with 126, 187, and 115, respectively, were obtained for the 3M 1860, 3M 1870, and Kimberly Clark PFR95-270 models when the user seal check was performed vs. not performed. Differences in the GM fit factors for the 3M 1860 and Kimberly Clark PFR95-270 models were statistically significant (p < 0.05) when performing a user seal check vs. not performing a user seal check. These data suggest that there may be some benefit to performing the user seal check for at least some models during the filtering facepiece respirator donning process for workers who have previously passed a fit test for those respirator models. Additional research is needed with larger groups of subjects and respirator models/types.
机译:这项研究的目的是更好地了解在N95过滤式面罩呼吸器佩戴过程中,用户密封检查步骤对呼吸器测试对象的好处。为使研究合格,受试者必须在以下三个N95过滤式面罩呼吸器型号中的至少一个上通过标准的定量拟合测试:3M 1860(杯形),3M 1870(平折)和Kimberly Clark PFR95-270(鸭嘴鸟)。招募了11名受试者,并进行了一系列简短的定量拟合测试,其中随机要求他们对每种模型的20种不同的呼吸器样品进行或不进行用户密封检查。实验设计包括3种呼吸器型号×10名受试者×2种治疗水平,重复10次。在所有模型和每个模型中,在有无用户密封检查的情况下,对每个受试者的几何平均(GM)拟合因子和达到拟合因子≥100的次数进行比较。与不执行用户密封检查相比,在执行用户密封检查时,对于11位受试者中的10位,在所有模型中获得了更高的GM拟合因子和更小的几何标准偏差。 3M 1860、3M 1870和Kimberly Clark PFR95-270型号在进行用户密封检查与未使用时相比,分别获得了148、184和156的几何平均拟合系数,分别为126、187和115。执行。 3M 1860和Kimberly Clark PFR95-270型号的GM拟合系数的差异在进行用户密封检查与不进行用户密封检查时具有统计学意义(p <0.05)。这些数据表明,对于以前通过了这些呼吸器型号拟合测试的工人,在过滤面罩呼吸器佩戴过程中,对至少某些型号的用户密封进行检查可能会有一些好处。对于较大的受试者和呼吸器型号/类型,还需要进行其他研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号