首页> 外文期刊>Journal of neurointerventional surgery >Perioperative safety of Hydrosoft coils
【24h】

Perioperative safety of Hydrosoft coils

机译:Hydrosoft线圈的围手术期安全性

获取原文
获取原文并翻译 | 示例
           

摘要

Objective: Hydrosoft coils were developed to serve as finishing coils to prevent aneurysmal recurrence at the neck. Initial animal studies were encouraging since some studies showed endothelial healing across the neck without recurrence over time. However, theoretical concerns exist regarding the potential threat to parent vessels as the Hydrosoft coils at the neck expand, as well as whether such coils can be adequately supple to safely serve as a true finishing coil. A retrospective review of the initial clinical experience utilizing Hydrosoft coils from three high-volume centers was performed. Methods: Each center was asked to report angiographic (aneurysmal location, aneurysmal maximal size, neck size, incidence of intraprocedural parent vessel thrombosis, coil herniation, aneurysmal rupture as well as Raymond scale and percent occlusion after coiling) and clinical (rupture status, Hunt and Hess grade, incidence of stroke, hemorrhage, vasospasm and hydrocephalus) data on consecutive patients who underwent placement of Hydrosoft coils. Results: A total of 141 patients were enrolled. Embolization achieved a Raymond Scale score of I (complete obliteration) in 79 aneurysms (56%), II (residual neck) in 40 aneurysms (28%) and III (residual dome) in 21 aneurysms (15%); in one case the Hydrosoft coil could not be placed. Procedural morbidity and mortality were 2.1% and 1.4%, respectively. No complications were definitively attributed to the use of Hydrosoft coils. There were three cases (2.1%) of parent vessel thrombosis, two of which resolved after intraprocedural administration of thrombolytic agents and did not lead to neurological sequelae. The incidences of intraprocedural or periprocedural aneurysmal rupture (2.1%), cerebral hemorrhage (3.5%), stroke (4.9%), vasospasm (26.2%) or hydrocephalus (31.1%) were comparable to contemporary literature. Conclusion: The use of Hydrosoft coils appears to be safe and does not lead to higher complication rates than are currently accepted in the literature. Further prospective studies are required to determine whether the use of Hydrosoft coils results in a lower incidence of aneurysmal recurrence.
机译:目的:开发了Hydrosoft卷材作为精整卷材,以防止颈部动脉瘤复发。最初的动物研究令人鼓舞,因为一些研究显示整个颈部的血管内皮愈合没有随着时间的推移而复发。但是,由于在颈部扩展的Hydrosoft线圈对母船的潜在威胁,以及这种线圈是否足够柔软以安全地用作真正的精加工线圈,存在着理论上的担忧。使用来自三个高容量中心的Hydrosoft卷材进行了初始临床经验的回顾性回顾。方法:要求每个中心报告血管造影(动脉瘤位置,最大动脉瘤大小,颈部大小,术中父母亲血管血栓形成的发生率,线圈疝,动脉瘤破裂以及雷蒙德鳞片和线圈闭塞百分比)和临床(破裂状态,亨特)和Hess等级,中风,出血,血管痉挛和脑积水的发生率)连续放置Hydrohydro线圈的患者的数据。结果:共纳入141例患者。栓塞治疗的Raymond量表在79个动脉瘤(56%)中达到I(完全闭塞),在40个动脉瘤(28%)中达到II(残余颈部),在21个动脉瘤(15%)中达到III(残余穹顶)。在一种情况下,无法放置Hydrosoft线圈。程序性发病率和死亡率分别为2.1%和1.4%。绝对没有并发症归因于使用Hydrosoft卷材。共有三例(2.1%)父母血管血栓形成,其中两例在术中给予溶栓剂后得以缓解,并且未导致神经系统后遗症。术中或术中动脉瘤破裂(2.1%),脑出血(3.5%),中风(4.9%),血管痉挛(26.2%)或脑积水(31.1%)的发生率与当代文献相当。结论:使用Hydrosoft弹簧圈似乎是安全的,并且不会导致比目前文献中接受的更高的并发症发生率。需要进一步的前瞻性研究来确定使用Hydrosoft弹簧圈是否会降低动脉瘤复发的发生率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号