首页> 外文期刊>Journal of Medical Virology >Comparison of the technical and clinical performance of the Elecsys HBsAg II assay with the Architect, AxSym, and Advia Centaur HBsAg screening assays.
【24h】

Comparison of the technical and clinical performance of the Elecsys HBsAg II assay with the Architect, AxSym, and Advia Centaur HBsAg screening assays.

机译:Elecsys HBsAg II分析与Architect,AxSym和Advia Centaur HBsAg筛选分析的技术和临床性能比较。

获取原文
获取原文并翻译 | 示例
           

摘要

South East Asia has some of the highest prevalence rates of hepatitis B virus (HBV) infection (>or=8%) in the world, and the emergence of hepatitis B surface antigen (HBsAg) mutant strains is a growing problem. Assays with the highest levels of sensitivity, including mutant detection, should be used for routine HBsAg screening. In this large multicenter study, the clinical and technical performance of the fully automated Elecsys HBsAg II assay was compared with the Architect, AxSYM, and Advia Centaur HBsAg assays for HBsAg screening. Nine laboratories (three each from Thailand, Korea, and Singapore) compared the Elecsys HBsAg II assay with their routine HBsAg screening assay against a range of stored and routine clinical samples, including recombinant mutants. The Elecsys HBsAg II assay demonstrated equivalent sensitivity and specificity to the Architect HBsAg assay. However, the Elecsys HBsAg II assay recognized a native mutant sample (L94S, L97V, L98V, T123A) that the Architect HBsAg assay failed to detect. The AxSYM and Advia Centaur HBsAg assays appeared less sensitive for the detection of early HBV infection and also failed to detect some of the recombinant mutant strains. There was almost complete agreement between the Elecsys HBsAg II assay and comparator assays with respect to routine serum samples. The results of this study demonstrate that the Elecsys HBsAg II assay is a highly sensitive and specific screening assay for HBsAg and detects reliably the most important and clinically relevant HBV mutants and genotypes. It is suitable for routine HBsAg screening in Asia.
机译:东南亚是世界上乙型肝炎病毒(HBV)感染率最高的国家之一(> == 8%),而乙型肝炎表面抗原(HBsAg)突变株的出现是一个日益严重的问题。常规HBsAg筛查应采用敏感性最高的检测方法,包括突变检测。在这项大型的多中心研究中,将全自动Elecsys HBsAg II检测的临床和技术性能与用于HBsAg筛选的Architect,AxSYM和Advia Centaur HBsAg检测进行了比较。九个实验室(分别来自泰国,韩国和新加坡的三个实验室)将Elecsys HBsAg II检测与常规HBsAg筛选检测与一系列存储和常规临床样品(包括重组突变体)进行了比较。 Elecsys HBsAg II试验证明与Architect HBsAg试验具有同等的敏感性和特异性。但是,Elecsys HBsAg II分析可以识别出建筑师HBsAg分析未能检测到的天然突变体样品(L94S,L97V,L98V,T123A)。 AxSYM和Advia Centaur HBsAg检测对早期HBV感染的检测灵敏度较低,并且也未能检测到某些重组突变株。对于常规血清样品,Elecsys HBsAg II测定法和比较剂测定法几乎完全一致。这项研究的结果表明,Elecsys HBsAg II检测是一种针对HBsAg的高度灵敏且特异的筛选检测方法,可可靠地检测出最重要和临床相关的HBV突变体和基因型。它适用于亚洲的常规HBsAg筛查。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号