首页> 外文期刊>Journal of Korean Institute of Metal and Materials >Premature Failure Analysis of Servovalve Components for a Thermal Power Plant
【24h】

Premature Failure Analysis of Servovalve Components for a Thermal Power Plant

机译:火力发电厂伺服阀组件过早失效分析

获取原文
获取原文并翻译 | 示例
           

摘要

The premature failure of a servovalve used for six months in a thermal power plant has been analyzed. The servovalve was made of stainless steel, containing 16Cr-0.44Mo, along with other elements. An overload of oil-supply pumping and an abnormal increase in the oil flux were observed during operation. A study revealed that erosion and corrosion could be the main causes of the failure. The visual examination of the servovalve did not show any appreciable damage. However, corrosion and erosion of the servovalve were observed using scanning electron microscopy (SEM). Upon examination of the servovalve, the corrosion was found to have occurred throughout the bushing and spool; however, erosion occurred at only the edge-side. In addition, the condition of the electrohydraulic control system (EHC) oil was investigated with respect to its satisfaction of the management standard.
机译:分析了在火力发电厂中使用了六个月的伺服阀的过早故障。伺服阀由含16Cr-0.44Mo的不锈钢以及其他元件制成。在操作过程中,观察到供油泵超载和油流量异常增加。一项研究表明,腐蚀和腐蚀可能是导致失效的主要原因。伺服阀的外观检查未发现任何明显的损坏。然而,使用扫描电子显微镜(SEM)观察到伺服阀的腐蚀和侵蚀。检查伺服阀后,发现在整个衬套和阀芯中都已发生腐蚀。但是,侵蚀仅发生在边缘侧。此外,针对电动液压控制系统(EHC)油是否满足管理标准进行了调查。