AIMS: To compare estimations of body composition using two different methods of bioelectrical impedance analysis (BIA) with dual X-ray absorptiometry (DXA) for estimating body composition during weight loss in overweight and obese young females. METHODS: Twenty-four overweight or obese females (age 29.5+/-6.1 years, BMI 36.4+/-4.3kg/m(2)) had body composition assessed using single-frequency (Tanita Ultimate Scaletrade mark; SF-BIA) and multi-frequency (Impedimed SFB7trade mark; MF-BIA) BIA and DXA before and after a 10-week weight loss intervention. RESULTS: MF-BIA estimates of body composition showed good absolute agreement with DXA, as evidenced by the small biases in the estimation of fat free mass (FFM), fat mass (FM) and percentage body fat (BF%); however, the limits of agreement for each variable were wide (bias +/-1.96 standard deviation; FFM -1.6+/-6.5kg, FM 1.6+/-6.5kg, BF% 1.4+/-6.3%). SF-BIA exhibited a larger bias with wide limits of agreement (FFM 3.8+/-9.1kg, FM -3.8+/-9.1kg, BF% -4.37+/-10.3%). During weight loss the values provided by MF-BIA and SF-BIA were not significantly different from DXA (p0.89) due to small bias and the limits of agreement were narrow (MF-BIA: FFM -0.01+/-3.74kg, FM 0.01+/-3.74kg, BF% 0.22+/-3.40%; SF-BIA: FFM 0.40+/-3.92kg, FM -0.40+/-3.92kg, BF% 0.25+/-3.40%). CONCLUSION: Compared with DXA, both the MF-BIA and SF-BIA accurately assessed changes in body composition with weight loss but, compared with SF-BIA, MF-BIA provided superior cross-sectional estimates of body composition.
机译:目的:为了比较使用两种不同的生物电阻抗分析(BIA)方法和双X射线吸收法(DXA)来估计超重和肥胖年轻女性体重减轻期间身体成分的身体成分估计。方法:二十四名超重或肥胖的女性(年龄29.5 +/- 6.1岁,BMI 36.4 +/- 4.3kg / m(2))采用单频(Tanita Ultimate ScaleTrade mark; SF-BIA)和在进行为期10周的减肥干预前后,多频(即为SFB7商标; MF-BIA)BIA和DXA。结果:MF-BIA人体成分估计值与DXA绝对吻合良好,无脂肪量(FFM),脂肪量(FM)和体脂百分比(BF%)的估算偏差较小。但是,每个变量的一致限制很宽(标准偏差+/- 1.96; FFM -1.6 +/- 6.5kg,FM 1.6 +/- 6.5kg,BF%1.4 +/- 6.3%)。 SF-BIA表现出较大的偏倚,且具有较宽的一致限制(FFM 3.8 +/- 9.1kg,FM -3.8 +/- 9.1kg,BF%-4.37 +/- 10.3%)。在减肥过程中,MF-BIA和SF-BIA提供的值与DXA(p0.89)的差异不大,因为偏倚小,并且一致的范围很窄(MF-BIA:FFM -0.01 +/- 3.74kg, FM 0.01 +/- 3.74kg,BF%0.22 +/- 3.40%; SF-BIA:FFM 0.40 +/- 3.92kg,FM -0.40 +/- 3.92kg,BF%0.25 +/- 3.40%)。结论:与DXA相比,MF-BIA和SF-BIA都能准确评估体重减轻的人体成分变化,但与SF-BIA相比,MF-BIA提供了更好的人体成分横截面估计。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号