首页> 外文期刊>Journal of electromyography and kinesiology: Official journal of the International Society of Electrophysiological Kinesiology >Reproducibility of kinematic motion coupling parameters during manual upper cervical axial rotation mobilization: A 3-dimensional in vitro study of the atlanto-axial joint
【24h】

Reproducibility of kinematic motion coupling parameters during manual upper cervical axial rotation mobilization: A 3-dimensional in vitro study of the atlanto-axial joint

机译:手动上颈椎轴向旋转运动期间运动学运动耦合参数的可再现性:寰枢关节的三维体外研究

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction: The reproducibility or the 3-dimensional (3D) kinematic aspects of motion coupling patterns of segmental manual mobilizing techniques is not yet known. This study analyzes the segmental 3D aspects of manual mobilization of the atlanto-axial joint in vitro. Methods and materials: Twenty fresh human cervical specimens were studied in a test retest situation with two examiners. The specimens were manually mobilized using three different techniques: a regional mobilization technique, it segmental mobilization technique on the atlas with manual fixation of the axis and a segmental mobilization applying a locking technique. Segmental kinematics were registered with a Zebris CMS20 ultrasound-based tracking system. The 3D aspects of motion coupling between main axial rotation and coupled lateral bending were analyzed by six parameters: the range of motion the three motion components, the cross-correlation, the ratio and the shift. Results: The results indicate stronger intra- than inter-examiner reproducibility. The range or motion of the axial rotation component shows a substantial level of intra- and inter-examiner reproducibility (ICC's 0.67 0.76). The parameters describing the coupling patterns show only moderate to substantial intra-examiner reproducibility for the more experienced of the two examiners (ICC's 0.55 0.68). All other correlations were not significant and no differences could be observed between regional versus segmental techniques. Conclusion: Reproducibility of segmental 3D-aspects of manual mobilization of the atlanto-axial joint in ail in vitro situation can differ between examiners. The results of the present study may indicate a possible tendency to higher reproducibility if mobilizations are performed by in examiner with high expertise and experience in applying the specific techniques. Continued investigation including more examiners with different levels of experience and different techniques is necessary to confirm these observations. (c) 2007 Elsevier Ltd. All rights reserved.
机译:简介:分段手动动员技术的运动耦合模式的可重现性或3维(3D)运动学方面尚不清楚。这项研究分析了体外动员寰枢关节的分段3D方面。方法和材料:在两名测试者的重新测试情况下,研究了二十份新鲜的人类宫颈标本。使用三种不同的技术手动移动标本:区域移动技术,通过手动固定轴的图集上的分段移动技术和使用锁定技术的分段移动。分段运动学已注册到基于Zebris CMS20超声的跟踪系统中。通过六个参数分析了主轴旋转和耦合的横向弯曲之间的运动耦合的3D方面:三个运动分量的运动范围,互相关,比率和偏移。结果:结果表明,内部检验者之间的再现性强于内部检验者。轴向旋转分量的范围或运动显示出考官内和考生间的可重复性水平很高(ICC为0.67 0.76)。描述耦合模式的参数对于两位审查员中经验更丰富的审查员而言,仅显示中等到充分的可重复性(ICC为0.55 0.68)。所有其他相关性均不显着,区域技术与分段技术之间也未观察到差异。结论:在所有体外情况下,手动动员寰枢关节的分段3D方面的可重复性在检查者之间可能有所不同。本研究的结果可能表明,如果调动是由具有较高专业知识和应用特定技术经验的审查员进行的,则可能具有更高的重现性。为了确认这些观察结果,有必要继续进行调查,包括更多具有不同经验和技术的检查员。 (c)2007 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号