首页> 外文期刊>Journal of glaucoma >Comparison of Intraocular Pressure Measurements Between Goldmann Applanation Tonometry and Reichert 7 Noncontact Tonometry
【24h】

Comparison of Intraocular Pressure Measurements Between Goldmann Applanation Tonometry and Reichert 7 Noncontact Tonometry

机译:Goldmann压平眼压计和Reichert 7非接触式眼压计眼压测量值的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose:The aim of this study was to compare the Reichert 7 (R7) noncontact tonometry with Goldmann applanation tonometry (GAT) and to determine the influence of central corneal thickness (CCT) in these measurements in the healthy population.Design:A prospective cross-sectional study.Methods:Intraocular pressure (IOP) of the right eyes of 120 patients was measured with GAT and R7. All patients were free of glaucoma. All the measurements were carried out between 7 am and 9 am The measurements with the R7 were taken in the automatic mode. After 15 minutes, IOP with GAT was measured followed by pachymetry. The R7 provided a Goldmann-correlated IOP (IOPg) and a corneal-compensated IOP (IOPcc).Results:The mean age of the patients was 53.919.3 (range, 26 to 85 y). The male/female ratio was 0.9/1. When R7 measurements were compared with GAT measurements, R7 measurements (both IOPcc and IOPg) were significantly higher than GAT measurements (P0.001). Besides that, IOPcc was significantly higher than IOPg (P0.001). There was a significant positive linear relationship between IOPcc and GAT (r=0.761, P0.001), and similar relationship between IOPg and GAT (r(2)=0.739, P0.001). The mean CCT was 545.9 +/- 33.2 m (range, 476 to 634 m). A weak correlation was observed between CCT and GAT (r=0.196, P=0.032). There was a significant correlation between CCT and IOPg (r=0.283, P=0.02). The correlation between CCT and IOPcc was not statistically significant (r=0.123, P=0.179).Conclusions:IOP values of R7 are higher than GAT values. However, IOPg was observed more coherent to the GAT values than IOPcc. IOPcc should be an evaluation factor along with GAT or IOPg in glaucoma examination.
机译:目的:本研究的目的是将Reichert 7(R7)非接触式眼压计与Goldmann压平眼压计(GAT)进行比较,并确定健康人群中这些测量中角膜中央厚度(CCT)的影响。方法:用GAT和R7对120例患者的右眼眼压(IOP)进行测量。所有患者均无青光眼。所有测量均在上午7点至上午9点之间进行。R7的测量是在自动模式下进行的。 15分钟后,测量GAT的IOP,然后进行测厚法。 R7提供了戈德曼相关的眼压(IOPg)和角膜补偿的眼压(IOPcc)。结果:患者的平均年龄为53.919.3(范围为26至85岁)。男女比例为0.9 / 1。当将R7测量值与GAT测量值进行比较时,R7测量值(IOPcc和IOPg)均显着高于GAT测量值(P0.001)。除此之外,IOPcc明显高于IOPg(P0.001)。 IOPcc与GAT之间存在显着的正线性关系(r = 0.761,P0.001),而IOPg与GAT之间具有相似的线性关系(r(2)= 0.739,P0.001)。平均CCT为545.9 +/- 33.2 m(范围为476至634 m)。在CCT和GAT之间观察到弱相关性(r = 0.196,P = 0.032)。 CCT与IOPg之间存在显着相关性(r = 0.283,P = 0.02)。 CCT与IOPcc之间的相关性无统计学意义(r = 0.123,P = 0.179)。结论:R7的IOP值高于GAT值。但是,与IOPcc相比,IOPg与GAT值更加一致。 IOPcc与青光眼检查中的GAT或IOPg一起应作为评估因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号